![Soyal AR-721KP User Manual Download Page 1](http://html1.mh-extra.com/html/soyal/ar-721kp/ar-721kp_user-manual_1338247001.webp)
SOYAL
ACCESS CONTROL SYSTEM
®
AR-721KP
V110810
EXIT
1 2 3 4 5 6
EXIT
1
2
3
4
5
6
7
f x2
4
N.C.
N.O.
COM
ERG
DLY
GND
12V
CN2
CN1
SG
ND
SW 1
SW 2
N.C
.
N.O
.
CO
M
1
2
3
4
5
6
7
COM
COM
N.C.
SGND
N.O.
EGR
DLY
12V
GND
GND
12V
GND
12V
N.O.
N.O.
CN1
CN2
Specification
Front Panel Indicators
Pull the cables from the square hole of the mounting plate.
Use a screwdriver to screw the base onto the wall.
Connect the terminal cables to the body and attach the body to the mounting plate.
Assemble the covers with the Allen key and screws (accessories supplied).
Turn on the power and LED will light and beep will sound.
Installstion
Contents
1
Product
2
User Guide
4
Specification
3
Tools
The unit should make a beep sound when any key on the keypad is depressed.
If no key is made within 30 seconds, it will automatically exit the programming mode.
In the programming mode: LED lightgreen and flash rapidly, it means that the unit waits for entering.
In the programming mode:
LED is red and flash rapidly, it means the reader is busy.
One beep sound mean acknowledge, two beep sounds mean not acknowledge.
Don’t equip controller and lock with the same power supply.
The power for controller may be unstable when the lock is
activating, that may make the controller malfunction.
The standard installation: Door relay and lock use the same
power supply, and controller use independent power supply.
Installation Notice
CN2
CN1
Wire Appllcation
Wire
Description
Relay_A
N.C.
1 N.C.
N.O.
2 N.O.
COM
3 COM
Exit Switch
EGR
4 Negative Trigger Input for Relay_A
DLY
5 Negative Trigger Input for Relay_B
Power
VIN-
6 DC Power GND
VIN+
7 DC Power
12V
Wire Appllcation
Wire
Description
Relay_B
COM
1 COM
N.O.
2 N.O.
N.C.
3 N.C.
T a m p e r
Switch
SW
4 N/O or N/C select via jumper
SW
5 COM
SGND
SGND 6 Signal Ground
Terminator
Electric Bolt
Keypad
Request To Exit
Request To Exit
POWER
12VDC
POWER
12VDC
POWER
12VDC
Diode
Electric Strike
Wiring Diagram
Users
500
Power consumption
< 2W
Memory
EEPROM
Weight(g)
100±10
Digits
3-6
Operating Temperature -20
℃
to +60
℃
Color
Gray/Silver
Housing Material ABS
Power Supply 9-16VDC / 100mA Indicator
1 Bi-Color LED&1Beeper Dimensions(mm) 111(L) x 77(W) x 26(H)
Delete user(s) code and Enable to system
Delete (Remove) a User Code from the system
Press
123456
(or Master Code)
→
14
UUU
→
Done
(
A green light and beep means that the user code was deleted.
)
[e.g.] Delete User address
10
:
Access programming mode
→
14 010
→
Done
Delete (Remove) all Users Codes from the system
Press
123456
(or Master Code)
→
29 29
→
Done
(
The LED flash red during 1 second to mean that the system is deleting all user codes.
Then a green light and beep means that all user codes were deleted.
)
Delete (Remove) a User Code from the controller
If you would like to delete all user codes. Remove the AR-721KP from the mounting plate. Press and hold the reset switch 10 seconds (RESTER, on
the KEYPAD circuit board). LED light green during 5 seconds and six beep sounds mean that all user are deleted.
Up to 500 pin-codes programmable from keypad.
Two access groups, each have request to exit inputs to control.
Default value: first group=
000~249 (Relat_A)
; second group=
250~499 (Relay_B)
.
2 relay outputs contact support latching or momentary outputs.
Built-in watchdog to prevent the system from halting.
Built-in tamper switch, include external security system interface.
Bell output, Press + together for bell using. (Optional)
Keypad will be locked for 30 seconds while continuous error operation.