background image

Introduction

WARNINGS

1

The Southwire 10030S multimeter measures AC and DC voltage, DC 

current, and resistance. It also tests continuity, diodes, and batteries. 

Readings are displayed on a large backlit LCD. This meter is fully 

tested and calibrated and, with proper use, will provide many years 

of reliable service.  

• Read, understand and follow the Safety Rules and Operating    

   Instructions in this manual before using this meter.
• The meter’s safety features may not protect the user if not  

   used in accordance to the manufacturer’s instructions. 
• Ensure that the test leads are fully seated in the input jacks and       

   keep fingers away from the metal probe tips when taking          

   measurements.
• Before changing functions using the rotary function switch,

   always disconnect the test leads from the circuit under test. 
• Use only UL listed test leads with the proper safety category rating. 
• Comply with all safety codes. Use approved personal protective  

  equipment when working near live electrical circuits - particularly  

  with regard to arc-flash potential.
• Use caution on live circuits. Voltages above 30 V AC RMS,

  42 V AC peak, or 60 V DC pose a shock hazard.
• Do not use meter or test leads if they appear damaged.
• Do not use the meter if it operates incorrectly. Protection may    

   be compromised. 
• Verify meter’s operation by measuring a known voltage. 
• Do not use the meter in wet or damp environments or during    

   electrical storms.
• Do not use the meter near explosive vapors, dust or gasses.
• Do not use the meter if it operates incorrectly. Protection may 

   be compromised.
• Replace the battery as soon as the low battery warning appears.  

2

Input Limits

Function 

 Maximum Input

AC Voltage  

DC Voltage 

DC Current

Resistance/Continuity

Diode

Battery Test

600V

600V, 200V on 200mV range

250V

250V for 15sec max.

250V for 15sec max.

250V

• Do not apply voltage or current that exceeds the meter’s    

   

   maximum rated input limit.

General Specifications

Diode Test      
Continuity Check 
Battery Test current
Input Impedance 
ACV Bandwidth
Display
Overrange indication 
Polarity    
Measurement Rate
Low Battery Indication
Battery
Operating Temperature 
Storage Temperature
Relative Humidity
Operating Altitude
Weight 
Size
Safety 

Insulation   

   

Class 2, Double Insulation

Overvoltage Category     

CAT III 300V, CAT II 600V

Test current of 1mA maximum, open circuit voltage 2.8V DC typical
Audible signal will sound if the resistance is approximately 30

Ω

 or less.

9V (6mA); 1.5V (100mA)
1M

Ω

45Hz to 450Hz
3 ½ digit, 2000 count LCD
“1” is displayed
Automatic, (-) negative polarity indication
2 times per second, nominal

 “         “  is displayed if battery voltage drops below operating voltage

one 9 volt (NEDA 1604) battery
32ºF to 104ºF (0ºC to 40ºC)
14ºF to 140ºF (-10ºC to 60ºC)
<80% 
7000ft (2000m) maximum
0.56lb (255g)
5.9” x 2.8” x 1.9” (15 x 70 x 48mm)
For indoor use and in accordance with Overvoltage Category 

III, Pollution Degree 2.

Conforms to UL 61010-1 v.2.

Summary of Contents for 10030S

Page 1: ...00 200 600 OFF 600 200 20V 2000 200 mV mV Instrucciones de uso 12 14 Rev 1 10030S manual Contents Made in China Product distributed by Southwire Company LLC One Southwire Drive Carrollton GA 30119 201...

Page 2: ...ot use the meter in wet or damp environments or during electrical storms Do not use the meter near explosive vapors dust or gasses Do not use the meter if it operates incorrectly Protection may be com...

Page 3: ...onent WARNING Operation is limited to CAT II applications when the insulated tips are removed from one or both test probes Refer to Input Limits section of this manual for maximum voltage ratings CAT...

Page 4: ...erve all safety precautions when working on live voltages WARNING 1 Set the rotary function switch to the 600V position 2 Insert the black test lead into the negative COM input jack and the red test l...

Page 5: ...serve all safety precautions when working on live circuits Do not measure current on circuits that exceed 250V Measurements in the 10A range should be limited to 30 seconds maximum every 15 minutes WA...

Page 6: ...ttery Test 1 Set the rotary function switch to the 1 5V or 9V BATT position 2 Insert the black test into the negative COM input jack and the red test lead into the positive V input jack 3 Touch the re...

Page 7: ...ts AC Voltage 200V 0 1V 600V 1V 1 2 reading 10 digits 50 60Hz 11 Operation Replacing the Fuses 1 Remove the two Phillips screws from the battery fuse door located on the back of the meter 2 Remove doo...

Page 8: ...product Whether Southwire repairs or replaces the product will be a determination that Southwire makes at its sole discretion SOUTHWIRE MAKES NO WARRANTY THAT THE PRODUCT WILL BE MERCHANTABLE OR FIT...

Page 9: ...ntalla LCD grande con luz de fondo Este metro est completamente compro bado y calibrado y bajo el uso apropiado proveer muchos a os de ZLY PJPV JVU HISL ADVERTENCIAS 3LH LU PLUKH ZPNH VKHZ SHZ 9LNSHZ...

Page 10: ...lasificaci n es la M S BAJA de cualquier componente individual ADVERTENCIA El funcionamiento est limitado a aplicaciones de CAT II cuando las puntas aisladas son retiradas de una o ambas sondas de pru...

Page 11: ...VERTENCIA 1 Mueva el interruptor rotario de funci n a la posici n de 600V 2 Inserte la sonda negra en la toma de entrada negativa COM y la sonda roja en la toma de entrada positiva V 3 Toque la punta...

Page 12: ...punto decimal apropiado y el valor Si la polaridad est invertida la pantalla indicar el signo de menos delante del valor Cumpla con todas las precauciones de seguridad al trabajar con circuitos activ...

Page 13: ...r una Bater a 1 Mueva el interruptor rotario de funci n a la posici n de 1 5V o 9V dependiendo del tipo de bater a 2 Inserte la sonda negra en la toma de entrada negativa COM y la sonda roja en la tom...

Page 14: ...0 1V 600V 1V 1 2 lectura 10 d gitos 50 60Hz 11 Cambio del Fusible 1 Retire dos tornillos Phillips de la cubierta de la bater a fusible 2 Retire la cubierta 3 Hale suavemente el fusible para retirarlo...

Page 15: ...DO PARA ALG N PROP SITO EN PARTICULAR SOUTHWIRE NO HACE NINGUNA OTRA GARANT A EXPRESA O IMPL CITA SALVO QUE LA GARANT A ESPEC FICAMENTE MENCIONADA EN ESTE P RRAFO SOUTHWIRE NO SER RESPONSABLE DE DA OS...

Reviews: