Southco EA-R03 Operating Instructions Download Page 1

EA-R03 Wireless Keypad Controller Kit

Operating Instructions

J-EA-R03-M_revC

visit

www.southco.com

for latest version of this document

Page 1 of 4

Package Contents

EA-R02-202 Receiver

EA-R03-103 Wireless Keypad Transmitter

Keypad Mounting Packet

Power/Auxiliary Connector Wire Harness

Lock/Unlock Relay Connector Wire Harness

User Instructions

EA-R03-103 Wireless Keypad Transmitter

1 · 2

3 · 4

5 · 6

7 · 8

9 · 0

1 · 2

3 · 4

5 · 6

7 · 8

9 · 0

EA-R02-202 Receiver

1.

Antenna

2.

Access Tab for Programming Switches

Features

Receiver supports up to four transmitters (one pre-programmed
wireless keypad transmitter included with kit)

Re-programmable user code (3 to 7 digits)

Selectable LOCK/UNLOCK pulse duration (250ms or 10sec)

Backlit keypad keys

Two user-configurable lock/unlock relay outputs

One 12V auxiliary relay output.

Specifications

Receiver Power:

12VDC (±10%)

Receiver Idle Current:

10mA (maximum), no attached devices

Receiver Operating Current:

100mA (maximum), no attached devices

Receiver Outputs:

three Form C relays, rated 15A at 14VDC

Receiver Operating Temp:

-20 to 80°C

Operating Range:

up to 60 feet / 18 meters (open air)

Operating Frequency:

433.92MHz

Coding Type:

Fixed Code (24-Bit)

Transmitter Power:

Type CR2032 3VDC battery

Normal Use

The keypad transmitter can be used to lock and unlock the system.

Unlocking the System

Enter the user code (default 1234), then press the 1·2 button. The system
will unlock and the auxiliary output will pulse twice, as shown in the figure
below:

UNLOCK Sequence (pulse set for 250ms)

UNLOCK Sequence (pulse set for 10 seconds)

Locking the System

Enter the user code (default 1234), then press the 3·4 button. The system
will lock and the auxiliary output will pulse once, as shown in the figure
below:

LOCK Sequence (pulse set for 250ms)

LOCK Sequence (pulse set for 10 seconds)

Pulsing Auxiliary Output

Enter the user code (default 1234), then press the 5·6 button. The auxiliary
output will pulse five times, as shown in the following figure:

Summary of Contents for EA-R03

Page 1: ...mA maximum no attached devices Receiver Operating Current 100mA maximum no attached devices Receiver Outputs three Form C relays rated 15A at 14VDC Receiver Operating Temp 20 to 80 C Operating Range up to 60 feet 18 meters open air Operating Frequency 433 92MHz Coding Type Fixed Code 24 Bit Transmitter Power Type CR2032 3VDC battery Normal Use The keypad transmitter can be used to lock and unlock ...

Page 2: ...rogramming switches on the EA R02 202 receiver s circuit board To access the switches remove the switch access tab by sliding the tab away from the receiver unit as shown below Two switches will be visible thru the tab window default positions shown Switch1 Used to enroll transmitters Default setting OFF position Switch 2 Used to set LOCK and UNLOCK pulse duration Switch2 Setting Duration ON defau...

Page 3: ...s shown in the following location The production date code is unique to each keypad Each production date code corresponds to a unique supervisor code that is required to reset the user code To obtain the supervisor code contact Southco and provide the production date code for your keypad Once the supervisor code is provided perform the following to reset the user code to 1234 1 Press the 9 0 butto...

Page 4: ...ment This equipment complies with all the requirements of DIRECTIVE 1999 5 EC OF THE EUROPEAN PARLIAMENT AND THE COUNCIL of March 9 1999 on radio equipment and telecommunication terminal Equipment and the mutual recognition of their conformity R TTE The R TTE Directive repeals and replaces in the directive 98 13 EEC Telecommunications Terminal Equipment and Satellite Earth Station Equipment as of ...

Reviews: