-24-
For Machines Mfd. Since 10/21
South Bend Tools
Model SB1118
P R E P A R A T I O N
1.
Clear all setup tools away from machine.
2.
Push EMERGENCY STOP button.
3.
Connect machine to power supply.
Test Run
After all preparation steps have been completed,
the machine and its safety features must be
tested to ensure correct operation. If you discover
a problem with the operation of the machine or
its safety components, do not operate it further
until you have resolved the problem.
Note:
Refer to Troubleshooting on Page 56
for solutions to common problems. If you need
additional help, contact our Tech Support or
(360) 734-1540.
Serious injury or death can result from using
this machine BEFORE understanding its
controls and related safety information. DO
NOT operate, or allow others to operate,
machine until the information is understood.
DO NOT start machine until all preceding
setup instructions have been performed.
Operating an improperly set up machine may
result in malfunction or unexpected results
that can lead to serious injury, death, or
machine/property damage.
To test run machine:
4.
Twist EMERGENCY STOP button clockwise
until it pops out (see Figure 26). This resets
switch so machine can start.
Figure
Figure 26. Resetting EMERGENCY STOP button.
. Resetting EMERGENCY STOP button.
STOP Button
T
o R
e
s
et
Twis
t
Clo
c
k
wiz
e
The test run consists of verifying the following:
• Power supply polarity is correct.
• Motors power up and run correctly.
• EMERGENCY STOP
button works
correctly.
• Headstock cover safety switch works correctly.
• Table limit switches work correctly.
5.
Verify power supply is connected to machine
with correct polarity by pressing TABLE UP
and TABLE DOWN buttons (see Figure 27).
— If table moves in same direction as button
description, power supply polarity is
correct.
— If table moves in opposite direction as
button description, stop machine and
DISCONNECT FROM POWER! Swap
"R" and "T" wire positions in power
supply junction box (see Figure 28), and
reconnect machine to power.
Figure
Figure 27. Control panel.
. Control panel.