Appendix V
167
A
p
p
en
d
ix
V
V-4 Terminal block control forward / reverse running jog
V-4-1 electrical diagram:
Three phase inputpower supply
380/400V 50/60Hz
%
Circuit breaker
Motor
M
FWDpoint motion/STOP
REV point motion/STOP
Terminals to control positive and reverse pointmovement
ST500
V-4-2 Connection:
Control terminal DI3 corresponds to jog command, control terminal DI4
corresponds to Jog command.
V-4-3 Parameter setting:
No.
Code
Parameter name
Setting range
F0.11 Command source selection
Terminal block control (LED on)
1
F1.02 DI3 terminal function selection Forward JOG (FJOG)
4
F1.03 DI4 terminal function selection Reverse JOG (RJOG)
5
V-5 Multi-speed running
V-5-1 electrical diagram
S1
S2
S3
S4
380/400V50/60Hz
Threephase input power supply
Circuit breaker
%
Motor
M
FWD/STOP
First segment speed
Second segment speed
Third segment speed
Multi segment speed operation
ST500