Chapter 5 Function parameter
49
Ch
ap
ter 5
335.
E1.03
3-stage speed setting 3X
-100.0% to 100.0%
0.0%
☆
336.
E1.04
4-stage speed setting 4X
-100.0% to 100.0%
0.0%
☆
337.
E1.05
5-stage speed setting 5X
-100.0% to 100.0%
0.0%
☆
338.
E1.06
6-stage speed setting 6X
-100.0% to 100.0%
0.0%
☆
339.
E1.07
7-stage speed setting 7X
-100.0% to 100.0%
0.0%
☆
340.
E1.08
8-stage speed setting 8X
-100.0% to 100.0%
0.0%
☆
341.
E1.09
9-stage speed setting 9X
-100.0% to 100.0%
0.0%
☆
342.
E1.10
10-stage speed setting 10X
-100.0% to 100.0%
0.0%
☆
343.
E1.11
11-stage speed setting 11X
-100.0% to 100.0%
0.0%
☆
344.
E1.12
12-stage speed setting 12X
-100.0% to 100.0%
0.0%
☆
345.
E1.13
13-stage speed setting 13X
-100.0% to 100.0%
0.0%
☆
346.
E1.14
14-stage speed setting 14X
-100.0% to 100.0%
0.0%
☆
347.
E1.15
15-stage speed setting 15X
-100.0% to 100.0%
0.0%
☆
348.
E1.16
Simple PLC running mode
0: stop after single running
1: hold final value after single
running
2: circulating
0
☆
349.
E1.17
Simple PLC power-down
memory selection
Units digit: power-down memory
selection
0: power-down without memory
1: power-down with memory
Tens digit: stop memory selection
0: stop without memory
1: stop with memory
11
☆
350.
E1.18
0 stage running time T0
0.0s(h) to 6500.0s(h)
0.0s(h)
☆
351.
E1.19
0 stage ac/deceleration time
selection
0 to 3
0
☆
352.
E1.20
1 stage running time T1
0.0s(h) to 6500.0s(h)
0.0s(h)
☆
353.
E1.21
1 stage ac/deceleration time
selection
0 to 3
0
☆
354.
E1.22
2 stage running time T2
0.0s(h) to 6500.0s(h)
0.0s(h)
☆
355.
E1.23
2 stage ac/deceleration time
selection
0 to 3
0
☆
356.
E1.24
3 stage running time T3
0.0s(h) to 6500.0s(h)
0.0s(h)
☆
357.
E1.25
3 stage ac/deceleration time
selection
0 to 3
0
☆
358.
E1.26
4 stage running time T4
0.0s(h) to 6500.0s(h)
0.0s(h)
☆