Hardware Specifications
Sourcefire 7000 Series Devices
Chapter 6
3D7110 and 3D7120 Sensing Interfaces
The 3D7110 and 3D7120 devices are delivered with eight-port copper or
eight-port fiber interfaces, each with configurable bypass capability.
Eight-Port 1000BASE-T Copper Interfaces
Use the following table to understand the activity and link LEDs on the copper
interfaces
Use the following table to understand the bypass LED on the copper interfaces.
Link LED
Activity LED
Bypass LED
3D7110 and 3D7120 Copper Link/Activity LEDs
S
TATUS
D
ESCRIPTION
Both LEDs off
The interface does not have link.
Link amber
The speed of the traffic on the interface is 10Mb or
100Mb.
Link green
The speed of the traffic on the interface is 1Gb.
Activity blinking
green
The interface has link and is passing traffic.
3D7110 and 3D7120 Copper Bypass LED
S
TATUS
D
ESCRIPTION
Off
The interface pair is not in bypass mode or has no power.
Steady green
The interface pair is ready to enter bypass mode.
Steady amber
The interface pair has been placed in bypass mode and is
not inspecting traffic.
Blinking amber
The interface pair is in bypass mode; that is, it has failed
open.