to all functions. Please refer to “7. LED DISPLAY AND BUTTONS OPERATION” at
page 10 for further information.
3. DMX Signal output: It transfers DMX signal to next fixture. Please use 3pin XLR
signal cable.
4. DMX signal input: It receives DMX signal from another fixture. Please use 3pin
XLR signal cable.
5. Power PLUG: This is a grounding-type plug with two poles and a third grounding
terminal. The third prong is provided for your safety. If the provided plug does not
fit into your outlet, refer to an electrician for replacement.
6. INSTALLATION
6.1. Rigging and Clamps
Pay attention to the safety! Please respectively consider the EN 60598-2-17
and the national standard during the installation. The authorized dealer must
only carry out the installation.
The installation of the fixture has to be built and constructed in a way that it can hold
10 times the weight for 1 hour without any harming demolish. The installation must al-
ways be secured with a secondary safety attachment, e.g. an appropriate catch net. This
secondary safety attachment must be constructed in a way that no part of the installa-
tion can fall down if the main attachment fails.
When rigging, de-rigging or servicing the fixture staying in the area below the instal-
lation place, on bridges, under high working places and other endangered areas is
forbidden. The operator has to make sure that the safety measure and the machine’s
technical installation is approved by an expert before taking into operation for the first
time and after changes before taking into operation anther time. He has also to make
sure that an expert approves safety measure and the machine’s technical installation
once a years.
WARNING: The fixture should be installed outside areas where persons may
walk by or be seated.
IMPORTANT: Overhead rigging requires extensive experience, including (but
not limited to) calculating working load limits, installation material being
used, and periodic safety inspection of all installation material and the pro-
jector. If you lack these qualifications, do not attempt the installation your-
self, but instead use a professional structural rigger. Improper installation can
result in bodily injury or property loss.
If the fixture shall be lowered from the ceiling or high joists, professional trussing
systems have to be used. The fixture must never be fixed swinging freely in the room.
8
ENGLISH
WF-U11 User manual