background image

O

P

E

R

A

T

IO

N

 M

A

N

U

A

L

PUBLIC ADDRESS SYSTEM

Please follow the instructions in this manual to obtain the optimum results from this unit.
We also recommend that you keep this manual handy for future reference.

          MIXER AMPLIFIER

120MA

0

0

0

0

0

1

1

1

1

1

2

2

2

2

2

3

3

3

3

3

4

4

4

4

4

5

5

5

5

5

6

6

6

6

6

7

7

7

7

7

8

8

8

8

8

9

9

9

9

9

10

10

10

10

10

0

0

0

1

2

3

4

5

6

7

8

9

10

OUTPUT  LEVEL

MIC 1

MIC 2

MIC 3

MIC 4

AUX

MASTER

TAPE

CD

TUNER

LINE

ON

OFF

POWER

BASS

TREBLE

-5

-5

-4

-4

-3

-3

-2

-2

-1

-1

+1

+1

+2

+2

+3

+3

+4

+4

+5

+5

MIXER AMPLIFIER

120MA

Summary of Contents for 120MA

Page 1: ...eep this manual handyfor future reference MIXER AMPLIFIER 120MA 0 0 0 0 0 1 1 1 1 1 2 2 2 2 2 3 3 3 3 3 4 4 4 4 4 5 5 5 5 5 6 6 6 6 6 7 7 7 7 7 8 8 8 8 8 9 9 9 9 9 10 10 10 10 10 0 0 0 1 2 3 4 5 6 7 8 9 10 OUTPUT LEVEL MIC 1 MIC 2 MIC 3 MIC 4 AUX MASTER TAPE CD TUNER LINE ON OFF POWER BASS TREBLE 5 5 4 4 3 3 2 2 1 1 1 1 2 2 3 3 4 4 5 5 MIXER AMPLIFIER 120MA ...

Page 2: ...CRIPTION 5 2 FEATURES 5 3 NOMENCLATURE AND FUNCTIONS 3 1 Front Panel 6 3 2 Rear Panel 4 CONNECTIONS 4 1 Speaker Connections 4 2 5 6 APPLICATIONS 10 7 SPECIFICATIONS 11 8 DIMENSIONAL DIAGRAM 12 7 8 8 9 XLR Connections MACHINE OPERATION ...

Page 3: ...e or electric shock Be sure to replace the unit s terminal cover after connection completion Because high voltage is applied to the speaker terminals never touch these terminals to avoid electric shock Be sure to ground to the safety ground earth terminal to avoid electric shock Never ground to a gas pipe as a catastrophic disaster may result Avoid installing or mounting the unit in unstable locat...

Page 4: ...oty smoke or steam as doing otherwise may result in fire or electric shock When the Unit is in Use Do not place heavy objects on the unit as this may cause it to fall or break which may result in personal injury and or property damage In addition the object itself may fall off and cause injury and or damage Make sure that the volume control is set to minimum position before power is switched on Lo...

Page 5: ...blending Built in 2 tone and 4 tone chime two options Pre OUT for other signal processing equipments Individual input volume and master volume control Current limiter overloading short circuit and thermal protection With remote priority input to select background music when paging 4 balanced XLR mic input with selectable priority and each with phantom power Constant voltage 100V and 70Vand 50V lin...

Page 6: ...OMENCLATURE AND FUNCTIONS 7 POWER Power indicator 8 OUTPUT LEVEL Power level indicator 9 TAPE Select tape channel input keyswitch 10 CD Select CD channel input keyswitch 11 TUNER Select tuner channel input keyswitch 12 LINE Select line channel input keyswitch 3 1 FRONT PANEL 1 2 3 6 4 5 7 8 9 10 11 12 6 0 0 0 0 0 1 1 1 1 1 2 2 2 2 2 3 3 3 3 3 4 4 4 4 4 5 5 5 5 5 6 6 6 6 6 7 7 7 7 7 8 8 8 8 8 9 9 9...

Page 7: ...d off on inputs 1 4 When set to the ON position phantom power 24V DC is available on INPUTS 1 4 mic position only 15 ADDRESS CODE 16 CHIME 2 Tone 4 Tone Chime 2 Tone 4 Tone volume Control 17 PHANTOM POWER MIC 1 4 phantom power select switch MIC4 ON OFF MIC PRIORITY MIC3 ON OFF MIC2 ON OFF MIC1 OFF ON 7 240V 50Hz T3 15AL 250V GAIN MIC 1 GAIN MIC 2 GAIN MIC 3 GAIN MIC 4 PHANTOM OFF ON PHANTOM OFF ON...

Page 8: ...ONNECTIONS 70V LINE 50V LINE 4 1 SPEAKER CONNECTIONS 4 2 XLR CONNECTIONS 4 70V 100V COM 4 50V 70V 100V COM 4 50V 70V 100V COM 4 50V 100V LINE 70V 100V COM 4 50V 50V 70V 50V 70V 120MA 120MA 120MA 21 41 83 8 ...

Page 9: ... 2 Power supply should match up to the machine The machine outfit with ground line so please plug on the connected ground wire net 4 As formidable shock or impact on machine such as thunder shock halfway signal pause excess rated signal input or other interference the machine will auto check and reopen automatically 3 9 ...

Page 10: ...OU DO NOT CONNECT EQUIPMENTS 6 APPLICATIONS REAR PANEL CONNECTIONS 10 240V 50Hz T3 15AL 250V GAIN MIC 1 GAIN MIC 2 GAIN MIC 3 GAIN MIC 4 PHANTOM OFF ON PHANTOM OFF ON PHANTOM OFF ON PHANTOM OFF ON 48V TAPE IN CD IN TUNER IN LINE IN PRE OUT AMP IN MIX OUT MIC1 MIC2 MIC3 ON OFF ON OFF ON OFF MIC PRIORITY ON OFF MIC4 2T 4T CHIME CHIME VOLUME REC OUT 4 100V 70V 50V COM CHIME REMOTE 48V 48V 48V XLR BAL...

Page 11: ...70Hz 16KHz 1 3dB 75 dB 350 mV 47 KÙ 350 mV 47 KÙ 48 V CONTROL BASS TREBLE CHIME OUTPUTS OUTPUT ELECTRO IMPEDANCE OUTPUT REC IMPEDANCE DISTORTION OPERATING CONDITION AC MAINS INPUT DIMENSIONS D X W X H mm POWER CONSUMPTION WEIGHT 0 1 200mV 470Ù 1000mV 470Ù 2 tone and 4 tone options 10 dB 10 dB 2 5 100mV 2KÙ XLR balanced with phantom power 353X484X88 200W 9 4Kg 240V 50Hz Specific voltage and frequen...

Page 12: ...PHANTOM OFF ON PHANTOM OFF ON 48V TAPE IN CD IN TUNER IN LINE IN PRE OUT AMP IN MIX OUT MIC1 MIC2 MIC3 ON OFF ON OFF ON OFF MIC PRIORITY ON OFF MIC4 2T 4T CHIME CHIME VOLUME REC OUT 4 100V 70V 50V COM CHIME REMOTE 48V 48V 48V XLR BAL 1 GND 2 HOT 3 COLD MIX OUT INPUTS RISQUE DE CHOC ELECTRIQUE NE PAS OUVRIR AVIS RISK OF ELECTRIC SHOCK DO NOT OPEN 1 2 3 1 2 3 1 2 3 1 2 3 BATT SUPPLY 24V 8A N17795 0 ...

Page 13: ...PUBLIC ADDRESS SYSTEM VersionV0 1 ...

Reviews: