background image

SIE Speaker –In-The-Ear 

RITE Receiver-In-The-Ear 

Wireless MFI Hearing 

Instrument  

U56 Series 

(LOGO) 

 

 

 

 

 

Rev 07/18 

Summary of Contents for U56 Series

Page 1: ...1 SIE Speaker In The Ear RITE Receiver In The Ear Wireless MFI Hearing Instrument U56 Series LOGO Rev 07 18 ...

Page 2: ...cates of channels Example 1 U32 3 U64 5 U128 SQ556 U128 2 U48 4 U96 1 Tube 2 Tube Plug 3 Microphone Ports 4 Dual Function Rocker Switch 5 Battery Door On Off Switch 6 Concha Lock 7 Sound Tip with Wax Stop 8 Serial Number 9 Manufacturer ID 10 Model ID ...

Page 3: ...il the plug clicks into place A zinc air type 13 battery is recommended but any 13 type or brand may be used To insert remove the adhesive label and wait thirty seconds for air activation Any moisture on the battery surface should be wiped off With the positive side up insert into the battery door To remove open the battery door and lift the battery out of the battery door Low battery indicator Wh...

Page 4: ...ity may leak and cause bodily harm Never attempt to recharge your batteries They may explode and cause serious injury Do not expose your batteries to heat such as an open flame microwave or oven There is a risk that they will explode and cause serious injury Please discard old batteries in a safe place Visit http www poison org prevent battery asp to learn more important information about battery ...

Page 5: ...will become as easy as putting on your glasses 1 Grasp hearing aid between your thumb and forefinger 2 Place it over your ear as shown 3 Gently push the ear tip into the ear canal 4 Tuck the concha lock into the bowl of your ear When positioned correctly your hearing aid is practically invisible Note It is important to remove the instrument by grasping the instrument itself Please DO NOT remove th...

Page 6: ...the life of the batteries Dual Function Rocker Switch Once the battery door is completely shut you will hear the unit turn on Each time you press the Dual Function Rocker Switch either higher or lower you will hear a quick double tone Press and release do not hold down rocker switch to adjust volume Once you ve reached either the maximum or minimum limit you will no longer hear the indicating tone...

Page 7: ...ograms simply press and hold the Dual Function Rocker switch either up or down for 2 seconds A voice prompt will announce the program change Press and hold again to change to next program Program one is automatically selected when the hearing aid is turned on Program one is the program of choice for most listening situations Dual Function Rocker Switch ...

Page 8: ...nt to keep your instruments as clean as possible Daily wipe your instruments tubing sound tip ear tips and or domes clean with a soft dry cloth carefully removing any traces of wax and debris A brush is provided to further assist you in cleaning After being disconnected from the tubing your ear tips and domes can be washed in lukewarm water with a mild detergent Reconnect after drying thoroughly P...

Page 9: ...o place Pull Wax stop from sound tip Wax stop Insertion Insert new Wax stop into sound tip pull the tool straight out The tool will release and the Wax stop will remain in place Press Wax stop firmly into sound tip making certain that is fully inserted Wax stops can be cleaned in hot water with a mild detergent drying thoroughly and then reused Recommend bringing into your hearing specialist routi...

Page 10: ...re shipped with a variety of accessories a sampling pictured above including the following Carrying Case Storage Case 1 card of batteries Battery holder Wax Stop Cleaning Tool If you have any questions about the use of these accessories please contact your hearing care professional ...

Page 11: ...11 ANSI SPECIFICATIONS Standard Tube ...

Page 12: ...12 ANSI SPECIFICATIONS Power Tube ...

Page 13: ...13 ANSI SPECIFICATIONS HiFit 110 Tube ...

Page 14: ...14 ANSI SPECIFICATIONS HiFit 125 Tube ...

Page 15: ...125 RITE Tube FCC ID 2AC2WSQ U56 FCC Regulator Statements This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation NOTE THE GRANTEE IS NOT RESPONSIBLE FOR ANY CHANGES OR MODIFICATIONS NOT EX...

Page 16: ...16 ...