Record Run
Rec Run
- Generator mode. The 633 sends running timecode while recording and stationary time-
code while not recording. Timecode in this mode defaults to the last stationary value at power-up.
When switching to Record Run from another mode, the internal generator will stop at the last num-
ber generated. A user-defined value can be jammed into the internal generator from the Setup Menu
option
TIMECODE > Set Generator TC
.
Free Run
Generator mode. Time code runs continuously. The value can be set by “jamming value” in the Setup
Menu option
TIMECODE/SYNC > Jam Menu
or by manually setting a value from the Setup Menu
option
TIMECODE/SYNC > Set Generator TC
.
Free Run Auto Mute
Functions the same as Free Run mode except timecode signal is muted from the LEMO output when
the 633 is in stopped mode. This allows rec-run functionality when Rec Run mode is not suitable
(e.g. Multi-camera shoots).
24h Run (24 hour Run)
Generator mode. Time code runs continuously. When this Time Code Mode is selected or when
the time/date is altered, the time code value is jammed to the value of the time-of-day clock. The
value can be set by “jamming value” in the Setup Menu option
TIMECODE/SYNC > Jam Menu
or by
manually setting a value from the Setup Menu option
TIMECODE/SYNC > Set Generator TC
.
24h Run Auto Mute
Functions the same as 24h Run mode except timecode signal is muted from the LEMO output when
the 633 is in stopped mode. This allows rec-run functionality when Rec Run mode is not suitable
(e.g. Multi-camera shoots).
External Timecode
Ext-TC
- Reader mode. The internal timecode generator follows an external timecode signal appear-
ing at the timecode input. If the external timecode is removed the internal generator stops as well.
Recording is triggered manually with the Transport Control.
External Timecode Auto-Record
Ext-TC Auto-Rec
- Reader mode. The internal timecode generator follows an external timecode sig-
nal appearing at the timecode input. If the external timecode is removed the internal generator stops
as well. The 633 automatically begins recording when running timecode is sensed. When stopped
timecode is sensed, recording stops. (
See “Meter Ballistics”, page 20
External Timecode Continuous
Ext-TC/Cont
- Reader mode. The internal timecode generator follows an external timecode signal
appearing at the timecode input. If the external timecode is removed the internal generator continues
to run to preserve continuous timecode. Recording is triggered manually with the Transport Control.
External Timecode Auto-Record Continuous
Ext-TC Auto-Rec/Cont
- Reader mode. The internal timecode generator follows an external timecode
signal appearing at the timecode input. If the external timecode is removed the internal generator
continues to run to preserve continuous timecode. The 633 automatically begins recording when run-
633 User Guide and Technical Information