- 33 -
SORHEA
G-FENCE
Choose different address on each Control Unit (UG) from 1 to 16, Indicated on each electronic card.
The address will only be taken into account when the Control Unit (UG) will be
powered.
In the case the address of a Control Unit (UG) already configured, is changed, do
the configuration of the detection cable(s) again. (see §5)
4.2 Wiring of the Termination / Link Unit (UT/UR)
Use of Termination/Link Unit
in “
UT
” mode:
Wiring of the Termination Unit is done on
Terminal 1 or Terminal 2
.
Move
the configuration switch to “UT” to initiate operating mode.
The switch for selection of the cable type is not used.
Use of Termination/Link Unit
in “
UR
” mode:
Wiring is done on Terminal 1 and Terminal 2.
Move
the configuration switch to “UR” to initiate operating mode.
The selection switch for the type of cable is configured in relation to the wiring of the detector
cable as explained below.
1 2 3 4
5 6 7 8
Terminal 1:
1 - Red wire of detector cable
2 - Black wire of detector cable
3 - Yellow wire of detector cable
4 - Green wire of detector cable
Terminal 2:
5 - Red wire of detector cable
6 - Black wire of detector cable
7 - Yellow wire of detector cable
8 - Green wire of detector cable
Selection switch for
type of cable
Configuration switch for
operating mode UT/UR
“Factory” switch:
Fixed position between
2 and 3
X
Example: UG with address 1