Camer
a
Con
tr
o
l
Command
s
Command Specification
44
[Parameter 1] <IN data (0 - 4095)>
[Parameter 2] <OUT data (0 - 4095)>
[Process] Sets the LUT value optionally.
x
LUT Value Setting (the case of gamma mode
2 and 4)
[Command] GAMMA
[Parameter 1] <Changing point (256 / 512 / 1024 /
2048 / 3072)>
[Parameter 2] <Strong and weak (1 - 5)>
[Process] Sets the LUT value at the 5 approximation
points.
x
LUT Value Setting (When gamma modes 6
and 7)
[Command] GAMMA
[Parameter 1] <Gamma value (0.00 - 1.00)>
([Parameter 2]) <Gamma offset value (0 - 4095)>
[Process] Sets the LUT value with a gamma value.
Filter Setting Command (XCL-5005
only)
x
Filter Mode Setting
[Command] FILTER-MODE
[Parameter 1] <Mode (0 - 2)>
0: OFF
1: Optional setting
2: Table setting
[Process] Sets the filter mode.
x
Filter Setting (the case of filter mode 1)
[Command] FILTER
[Parameter 1] <Address (11 / 12 / 13 / 21 / 22 / 23 / 31 /
32 / 33)>
[Parameter 2] <Filter factor (± 0.000 – ±10.000)>
[Process] Sets the filter optionally.
x
Filter Setting (the case of filter mode 2)
[Command] FILTER
[Parameter 1] <Table pattern (1 - 6)>
[Process] Sets the filter table pattern.
Binning / Partial Setting Command
x
Binning Mode Setting (XCL-5005 only)
[Command] BINNING
[Parameter 1] <Mode (0 - 1)>
0: OFF
1: ON
[Process] Sets the binning mode.
x
Partial Scan Setting
[Command] PARTIAL
[Parameter 1] <Mode (0 - 5)>
0: OFF
1: Divided into 16 (XCL-5000 compatible)
2: Divided into 32 (XCL-5000 compatible)
3: Divided into 16
4: Divided into 32
5: Divided into arbitrary number
(When divided into 16)
([Parameter 2]) <Read beginning point (0 - 15)>
([Parameter 3]) <Read block number (0 - 15)>
(When divided into 32)
([Parameter 2]) <Read beginning point (0 - 31)>
([Parameter 3]) <Read block number (0 - 31)>
(When divided into arbitrary number)
([Parameter 2]) <Read beginning point (0 - 408)>
([Parameter 3]) <Read line number (1 - 2050)>
[Process] Specifies the mode setting of partial scan with
Parameter 1, and the read area for when scan
operation with Parameter 2 and Parameter 3.
The range of setting values is as follows. Any other
value is invalid.
The XCL-5005CR sets an even value to Parameter 2
by placing a primary color filter.
(When divided into 16)
| Read beginning po read line number |
≤
15
(When divided into 32)
| Read beginning po read line number |
≤
31
(When divided into arbitrary number)
| Read beginning position × 5 + read line number |
≤
2050
x
Partial Scan Offset Setting
[Command] PARTIAL-OFFSET
[Parameter 1] <Offset value (0 - 51)>
[Process] Sets offset for partial scan read beginning
position.
When the partial scan setting is set to Modes 1 to 4
(divided into 16 or 32), the setting range for the offset
value (Parameter 1) is 0 to 38.
The XCL-5005CR sets an even value for the offset
value (Parameter 1) by placing a primary color filter.
x
Horizontal Partial Scan Setting
[Command] HPARTIAL
[Parameter 1] <Mode (0 - 1)>
0: OFF
1: ON
[Parameter 2] <Read column number (128 - 2448)>
[Process] Sets the read column number for when
horizontal partial scan operation.
Set the read column number (Parameter 2) to a
multiple of 4 between the range of 128 to 2448.
IN/OUT Setting Command
x
External Trigger Signal Input Selection
[Command] EXTTRG
[Parameter 1] <Input specification (0 - 1)>
0: Camera Link
t
DIGITAL IF connector
1: DC
t
DC IN connector