![Sony XCL5005 Technical Manual Download Page 43](http://html.mh-extra.com/html/sony/xcl5005/xcl5005_technical-manual_418408043.webp)
Camer
a
Con
tr
o
l
Command
s
Command Specification
43
x
Black Clamp Level Setting (Right side of the
window)
[Command] BBALANCE-R
[Parameter 1] <Mode (1 - 2)>
1: Automatic adjustment method
2: Direct adjustment method
(When automatic adjustment method)
([Parameter 2]) <Black clamp level correction value
(±1023)>
(When direct adjustment method)
([Parameter 2]) <Black clamp level adjusting value (0 -
2047)>
[Process] Sets the black clamp level setting and black
clamp level adjusting or correction value on the right
side of the window.
x
RGB Red Correction Setting
[Command] RCORR
[Parameter 1] <Correction value (±255)>
[Process] Sets red correction for when RGB output.
x
RGB Green Correction Setting
[Command] GCORR
[Parameter 1] <Correction value (±255)>
[Process] Sets green correction for when RGB output.
x
RGB Blue Correction Setting
[Command] BCORR
[Parameter 1] <Correction value (±255)>
[Process] Sets blue correction for when RGB output.
Digital Setting Command
x
Digital Gain Setting (XCL-5005 only)
[Command] DGAIN
[Parameter 1] <Mode (0 - 1)>
0: OFF
1: ON
[Process] Sets the digital gain.
x
Digital Gain-Step Setting (XCL-5005 only)
[Command] DGAIN-STEP
[Parameter 1] <Gain (0 - 128)>
[Process] Sets and fine adjusts the digital gain.
x
Digital Pedestal Setting
[Command] DPEDESTAL
[Parameter 1] <Mode (0 - 1)>
0: OFF
1: ON
([Parameter 2]) <Pedestal level (0 - 255)>
[Process] Sets the digital pedestal level.
x
Automatic Clamp Control Setting
[Command] AUTO-DCLAMP
[Parameter 1] <Mode (0 - 1)>
0: OFF
1: ON
([Parameter 2]) <Clamp setting value (0 - 65535)>
[Process] Sets the automatic clamp control and the
clamp setting value.
x
Automatic Clamp Control Correlation Factor
Setting
[Command] ADC-COEF
[Parameter 1] <Correlation factor (0 - 4095)>
[Process] Sets the automatic clamp control correlation
factor.
x
Digital Clamp Setting
[Command] DCLAMP
[Parameter 1] <Mode (0 - 1)>
0: OFF
1: ON
([Parameter 2]) <Clamp adjusting value (± 255)>
[Process] Sets the digital clamp and the clamp adjusting
value.
x
Digital Clamp Setting (Left side of the
window)
[Command] DCLAMP-L
[Parameter 1] <Mode (0 - 1)>
0: OFF
1: ON
([Parameter 2]) <Clamp adjusting value (± 255)>
[Process] Sets the digital clamp and the clamp adjusting
value on the left side of the window.
x
Digital Clamp Setting (Right side of the
window)
[Command] DCLAMP-R
[Parameter 1] <Mode (0 - 1)>
0: OFF
1: ON
([Parameter 2]) <Clamp adjusting value (± 255)>
[Process] Sets the digital clamp and the clamp adjusting
value on the right side of the window.
Gamma Setting Command
x
Gamma Correction Mode Setting
[Command] GAMMA-MODE
[Parameter 1] <Mode (0 - 7)>
0: OFF
1: Optional setting
2: 5 points approximation
3: Optional setting (Setting value is not saved.)
4: 5 approximation points (Setting value is not
saved.)
5: Default setting
6: Gamma value setting
7: Gamma value setting (Setting value not saved.)
[Process] Sets the gamma mode.
Setting gamma mode 5 initializes LUT value.
x
LUT Value Setting (the case of gamma mode
1 and 3)
[Command] GAMMA