![Sony XCL5005 Technical Manual Download Page 22](http://html.mh-extra.com/html/sony/xcl5005/xcl5005_technical-manual_418408022.webp)
F
u
nc
ti
ons
4. Camera mode
22
4.2.5.
Trigger binning mode
In this mode the binning action begins through
synchronization with the external trigger input.
1
T 1
T2
T3
1025 H
2448 CLK
72 CLK
1025
1
1025
T 4
Trigger binning
FVAL
LVAL
DVAL
Video
output
(The horizontal timing is the same as in the normal mode.)
TRG
*
*
There is only one LVAL which is less than 2448 CLK during T4
length in order to adjust the timing. T4 changes by depending
on T1.
Trigger mode
T1
T2
Shutter
T3 [ms]
Edge detection
mode
More than 34 ms
More than 10 µs
OFF
67
1/30 s
33.66
1/100 s
10.32
1/120 s
8.64
1/250 s
4.32
1/500 s
2.32
1/1000 s
1.32
1/2000 s
0.82
1/5000 s
0.52
1/10000 s
0.42
1/15 s
67
1/7.5 s
135.1
1/2 s
509.2
1 s
1000
2 s
2000
Width detection
mode
More than 34 ms
More than 10 µs and
less than 2 s
–
T2 + 0.33