Troubleshooting
Indicators
The picture is not clear.
• Picture is out of focus.
c
Adjust the focus.
• Condensation has occurred on the lens.
c
Leave the projector for about two hours with the power on.
The image extends beyond
the screen.
• The APA key is pressed although there are black edges around the
image.
c
Display the full image on the screen and press the APA key.
c
Adjust Shift in the INPUT SETTING menu properly.
The picture flickers.
• Dot Phase in the INPUT SETTING menu has not been adjusted
properly.
c
Adjust Dot Phase in the INPUT SETTING menu properly.
POWER SAVING
Lights up when the projector is in power saving mode
TEMP/FAN
Lights up when temperature inside the projector becomes unusually
high. Check to see if anything is blocking the ventilation holes.
Flashes when the fan is broken. Consult with qualified Sony
personnel.
LAMP/COVER
Lights up when the lamp has reached the end of its life or becomes a
high temperature. Wait for 120 seconds to cool down the lamp and
turn on the power again, or replace the lamp.
Or the electrical system may break down. Consult with qualified
Sony personnel.
Flashes when the lamp cover is not secured firmly. Attach the cover
securely.
I
/
1
indicator
Lights in red when the projector is in standby mode. Once in standby
mode, you can turn on the projector with the
I
/
1
key.
Lights in green when the power is turned on.
Flashes in green for about several seconds from the projector is
turned on until the projector is ready to operate. Also, flashes in
green for about 120 seconds while the cooling fan runs after the
power is turned off with the
I
/
1
key. During this time, you will not
be able to operate on the projector.
Symptom
Cause and Remedy