Symptom

Cause/Measures

• Check that the USB-PSTN modem adaptor is

correctly connected to the USB terminal of your
USB network adaptor compatible camcorder. If
it is not, reconnect it.

• The AREA CODE switch is incorrectly set.

c

Set it correctly. For details, see “Setting up
the unit” (page 11).

• The line is busy. (Another device is using the

phone line.)

c

Try again when the other device has stopped
communicating.

• Cannot connect to the other telephone line.

c

Wait a while before trying again.

• Cannot communicate well sometimes

depending on the status of the telephone line.

c

Turn off the camcorder, turn it back on, then
try to communicate again.

• The USB-PSTN modem adaptor cannot be used

with a home or business telephone line. (Never
connect it to a home or business telephone line.
Doing so can lead to malfunction, overheating
and fire.)

A USB error occurs
ex) Connection Error

Connect USB Device

A PPP error occurs
ex) Connection Error

Check phone line

Summary of Contents for UNA-PSTN

Page 1: ...wner s Record The model and serial numbers are located on the bottom of the unit Record the serial number in the space provided below Refer to these numbers whenever you call upon your Sony dealer regarding this product Model No UNA PSTN Serial No UNA PSTN 2003 Sony Corporation ...

Page 2: ... not expressly approved in this manual could void your authority to operate this equipment THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS 1 THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE AND 2 THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION NOTE This equipment has been tested and fo...

Page 3: ...ne network must comply with the applicable FCC Part 68 rules and requirements adopted by the ACTA This modem uses the USOC RJ 11 telephone jack A plug and jack used to connect this equipment to the premises wiring and telephone network must comply with the applicable FCC Part 68 rules and requirements adopted by the ACTA A compliant telephone cord and modular plug is provided with this product It ...

Page 4: ...9 or write to the Sony Customer Information Service Center at 12451 Gateway Blvd Fort Myers Fl 33913 for repair and or warranty information If the equipment is causing harm to the telephone network the telephone company may request you remove the equipment until the problem is resolved Repair of this equipment should be made only by a Sony Service Center or Sony authorized agent For the Sony Servi...

Page 5: ...able Industry Canada technical specifications The Ringer Equivalence Number REN is an indication of the maximum number of devices allowed to be connected to a telephone interface The termination on an interface may consist of any combination of devices subject only to the requirement that the sum of the RENs of all the devices does not exceed five ...

Page 6: ...999 5 EC R TTE to be connected with all European analogue PSTN However due to differences between the individual PSTNs provided in the different countries the compliance does not on itself give an unconditional assurance of successful operation on every PSTN network termination point In the event of problems you should contact your equipment supplier in the first instance If the plug of exclusive ...

Page 7: ...ion manual are in general registered trademarks or trademarks of their respective developing manufacturers This instruction manual does not specify and signs Table of contents Precautions on Use 8 Precautions on Handling 9 Maintenance 9 Parts identification 10 Before Use 10 Setting up the unit 11 Preparation 14 Connecting to a telephone line with a PSTN modem adaptor 14 Accessing the Internet 15 D...

Page 8: ...ecified in this manual may lead to fire or breakdown Avoid incorrect connection Do not allow any small pieces of metal inside the connector A short between pins may lead to fire or breakdown Insert the connector completely straight Inserting it at an angle can cause a short between pins which may lead to fire or breakdown Unplug the telephone cable before moving the USB PSTN modem adaptor Moving i...

Page 9: ...going flat Do not lift your camcorder by the USB PSTN modem adaptor or its cable Do not pull out the connector by pulling the cable Do not bend or apply excessive force to the cable Maintenance Wipe the USB PSTN modem adaptor with a soft dry cloth If the USB PSTN modem adaptor is very dirty wipe it using a cloth with a little neutral solvent added and then wipe it dry again Do not use thinners ben...

Page 10: ...nnector 5 RJ 11 connector 6 Switch cover 7 AREA CODE switches 8 TONE P1 PULSE10 P2 PULSE20 selector USB connector For connection to USB compatible camcorders RJ 11 connector For connection to a telephone cable Before Use This USB PSTN modem adaptor is exclusively for use with a USB network adaptor compatible camcorder Before use refer to your Network Function Application Operating Instructions ...

Page 11: ...with the TONE P1 PULSE10 P2 PULSE20 selector TONE When your phone line has tone signaling PULSE10 When your phone line has pulse signaling PULSE20 Normally this is not used For details see To check the dial speed of a pulse dialing phone on page 12 zTips How can I tell if my phone has tone signaling You can hear the touch pad sound from your phone when you press the number button How can I tell if...

Page 12: ...as TONE P1 PULSE10 P2 PULSE20 setting is not required In such a country or area the USB PSTN modem adaptor communicates by the telecom protocol in that country or area regardless of the TONE P1 PULSE10 P2 PULSE20 setting To check the dial speed of a pulse dialing phone You can change the dialing speeds of some pulse dial phones To check the dial speed switch the dial speed selector on the phone an...

Page 13: ...table and the switch positions is as illustrated below e g when you set to Japan e g when you set to the USA The setup list for the AREA CODE switch Japan 000000 Greece 110100 Sweden 010110 United States 100000 Ireland 101100 Switzerland 110110 Australia 010000 Italy 011100 Taiwan 001110 Austria 110000 Netherlands 010010 United Kingdom 101110 Belgium 001000 New Zealand 110010 Canada 100000 Denmark...

Page 14: ...modem adaptor to a USB network adaptor compatible camcorder Connecting to a telephone line with a PSTN modem adaptor Connect to the Internet via a telephone line using a USB PSTN modem adaptor 1 Connect the supplied telephone cable to this unit and the modular jack of the telephone ...

Page 15: ...network adaptor compatible camcorder s power switch to MEMORY NETWORK to display the Network Menu Your camcorder is now ready for communication Note Connect the USB PSTN modem adaptor directly to your USB network adaptor compatible camcorder The camcorder is not compatible with a USB hub Accessing the Internet For details of how to log on refer to your USB network adaptor compatible camcorder s Ne...

Page 16: ... Disconnecting the USB PSTN modem adaptor from your camcorder 1 Remove the USB PSTN modem adaptor s USB connector from USB jack of your camcorder 2 Remove the telephone cable from the USB PSTN modem adaptor ...

Page 17: ... it correctly For details see Setting up the unit page 11 The line is busy Another device is using the phone line c Try again when the other device has stopped communicating Cannot connect to the other telephone line c Wait a while before trying again Cannot communicate well sometimes depending on the status of the telephone line c Turn off the camcorder turn it back on then try to communicate aga...

Page 18: ...6800 19200 21600 24000 26400 28800 31200 33600 34000 34667 36000 37333 38000 38667 40000 41333 42000 42667 44000 45333 46000 46667 48000 49333 50000 50667 52000 53333 54000 54667 56000 bps Modulation mode standard ITU T V 21 V 22 V 22bis V 32 V 32bis V 34 V 90 BELL 212A 103 K56flex Sender sensitivity 10 to 15 dBm Error correction MNP Class 4 10 ITU T V 42 Data compression MNP Class 5 ITU T V 42bis...

Page 19: ...65 mm 3 1 2 11 16 2 5 8 in width height depth Weight approx 54 g 1 9 oz Operating temperature 0 C 40 C Storage temperature 20 C 60 C Accessories Telephone cable 1 Operating Instructions Design and specifications are subject to change without notice ...

Page 20: ...e B est conforme à la norme NMB 003 du Canada Conditions d utilisation L utilisation est sujette aux deux conditions suivantes 1 ce dispositif ne doit pas produire d interférences et 2 ce dispositif doit accepter toutes les interférences reçues y compris les interférences qui peuvent provoquer un fonctionnement non souhaité du dispositif AVIS DE L INDUSTRIE CANADA Le présent matériel est conforme ...

Page 21: ... EC R TTE pour être connecté à tous les PSTN analogues européens Cependant étant donné que des différences existent entre les PSTNs individuels fournis dans chaque pays la conformité à la directive ne garantit pas de façon inconditionnelle le bon fonctionnement des points d arrivée de tous les réseaux PSTN En cas de problème contactez avant toute chose votre fournisseur local Au cas où la prise d ...

Page 22: ... sont en général des marques enregistrées ou des marques appartenant aux fabricants qui les ont mises au point Aucun signe ou ne les précède dans ce manuel Table des matières Précautions d utilisation 5 Précautions de manipulation 6 Entretien 6 Nomenclature des pièces 7 Avant la mise en service 7 Configuration de l unité 8 Préparation 11 Connexion à une ligne de téléphone via un adaptateur modem P...

Page 23: ...un incendie ou de détériorer le dispositif Evitez les connexions incorrectes Ne laissez pas des morceaux de métal dans les connecteurs Un court circuit entre les broches peut être à l origine d un incendie ou détériorer le dispositif Insérez le connecteur bien droit S il est rentré en biais il peut se produire un court circuit entre les broches avec les risques d incendie ou de détérioration du di...

Page 24: ...pas le caméscope par l adaptateur modem USB PSTN ou par le câble Ne tirez pas le connecteur par le câble Ne pliez pas le câble et ne le forcez pas Entretien Essuyez l adaptateur modem USB PSTN avec un chiffon doux et sec S il est très sale appliquez un détergent neutre sur le chiffon que vous essuierez ensuite avec un chiffon sec N utilisez jamais de diluants de benzine d alcool ou autre produits ...

Page 25: ... RJ 11 6 Cache de commutateur 7 Commutateurs de AREA CODE 8 Sélecteur TONE P1 PULSE10 P2 PULSE20 Connecteur USB Pour connecter un caméscope compatible USB Connecteur RJ 11 Pour connecteur un câble de téléphone Avant la mise en service Cet adaptateur modem USB PSTN doit exclusivement être utilisé avec un caméscope compatible avec une carte réseau USB Avant de le mettre en service consultez les Dire...

Page 26: ...honique sur le sélecteur TONE P1 PULSE10 P2 PULSE20 TONE Si votre ligne téléphonique est à signalisation multifréquences PULSE10 Si votre ligne téléphonique est à impulsions PULSE20 Normalement inutilisé Pour plus de détails voir Vérification de la vitesse de numérotation d un appareil à impulsions à la page 9 zConseils Comment savoir si mon téléphone est à signalisation multifréquences Vous enten...

Page 27: ...écessaire Ceci du fait que dans ces régions l adaptateur modem USB PSTN communique via le protocole de télécommunication de cette région ou de ce pays lequel ne tient pas compte de la configuration TONE P1 PULSE10 P2 PULSE20 Pour vérifier la vitesse de numérotation d un téléphone à signalisation par impulsion cadran Sur certains téléphones à impulsions vous pouvez modifier la vitesse de numérotati...

Page 28: ...e les numéros à 6 chiffres et la position du commutateur sont indiqués ci dessous pour un réglage sur Japon pour un réglage sur Etats Unis Liste des réglages du commutateur AREA CODE Japon 000000 Grèce 110100 Suède 010110 Etats Unis 100000 Irlande 101100 Suisse 110110 Australie 010000 Italie 011100 Taiwan 001110 Autriche 110000 Pays Bas 010010 Royaume Uni 101110 Belgique 001000 Nouvelle Zélande 11...

Page 29: ...USB PSTN au caméscope compatible avec un adaptateur de réseau USB Connexion à une ligne de téléphone via un adaptateur modem PSTN Connexion à Internet via une ligne de téléphone avec un adaptateur modem USB PSTN 1 Connectez le câble de téléphone fourni à l unité et à la prise de téléphone modulaire ...

Page 30: ...teur du caméscope compatible avec un adaptateur réseau USB sur MEMORY NETWORK pour afficher le menu réseau Votre caméscope est maintenant prêt pour la communication Remarque Connectez directement l adaptateur modem USB PSTN sur votre caméscope compatible avec un adaptateur réseau USB Le caméscope n est pas compatible avec un concentrateur USB Accès à Internet Les détails pour entamer une session s...

Page 31: ...nnexion de l adaptateur modem USB PSTN et du caméscope 1 Retirez le connecteur USB de l adaptateur modem USB PSTN de la prise USB de votre caméscope 2 Retirez le câble de téléphone de l adaptateur modem USB PSTN ...

Page 32: ...de l unité page 8 La ligne est occupée Un autre appareil occupe la ligne c Essayez de nouveau lorsque l autre appareil aura terminé sa communication Impossible de connecter une autre ligne de téléphone c Attendez un moment avant de recommencer La communication n est pas toujours bonne en fonction du statut de la ligne de téléphone c Eteignez le caméscope rallumez le et essayez de nouveau d établir...

Page 33: ...16800 19200 21600 24000 26400 28800 31200 33600 34000 34667 36000 37333 38000 38667 40000 41333 42000 42667 44000 45333 46000 46667 48000 49333 50000 50667 52000 53333 54000 54667 56000 bps Norme de modulation ITU T V 21 V 22 V 22bis V 32 V 32bis V 34 V 90 BELL 212A 103 K56flex Sensibilité d envoi 10 à 15 dBm Correction d erreur MNP Classe 4 10 ITU T V 42 Compression des données MNP Classe 5 ITU T...

Page 34: ...m 3 1 2 11 16 2 5 8 po largeur hauteur profondeur Poids approximatif 54 g 1 9 on Température de fonctionnement 0 C à 40 C Température de stockage 20 C à 60 C Accessoires Câble de téléphone 1 Consignes d exploitation La conception et les spécifications peuvent être modifiées sans avis préalable ...

Page 35: ......

Page 36: ...Sony Corporation Printed in Japan Printed on 100 recycled paper using VOC Volatile Organic Compound free vegetable oil based ink ...

Reviews: