Section 5
Electrical Alignment
When any board of this unit is repaired or replaced, adjust this unit for electrical adjustments as this section.
Note
“5-4. Video System Level Adjustment”
according to the system that the customer uses.
• Master setup unit MSU-1000/1500 is used for electrical adjustments of the unit.
Without using master setup unit (here after MSU), the electrical alignment also can be made using setting menu
of the camera.
Refer to
“5-1-7. Setup Menu Correspondence List”
5-1.
Preparations
Turn on the external main power switch before starting adjustments, and warm up the unit for about 10 minutes.
5-1-1.
Required Equipment, Tool
Note
Use calibrated equipment and tools.
Equipment Required
Name
Equipment
HD waveform monitor
Leader Electronics LV5150DA, Leader Electronics LV5152DA
(multi format) or equivalent
HD color monitor
Sony BVM-D20F1J/BVM-D14H5J or equivalent
Oscilloscope
Tektronix TDS460A or equivalent
Master setup unit
Sony MSU-1000/1500
HD viewfinder
Sony HDVF-20A/200/C30WR/C35W
Lens
Canon HJ18 or equivalent
Tool
Name
Sony Part No.
Remarks
Grayscale chart (16 : 9 reflective type)
—
Commercially available
Since time degradation is appeared, re-
place for every two years. (The exchange
time, change by the safekeeping situa-
tion.)
Grayscale chart (16 : 9 transparent type)
J-6394-080-A
Use when the grayscale chart (16 : 9 re-
flective type) is not available.
Pattern box PTB-500
J-6029-140-B
5-1-2.
File Data at Adjustment
The file structure of the adjustment data of this unit is as follows.
HDC4300
5-1