Chapter 2 Specifications
2.3. Environmental Specifications
Note
The specifications which apply when media is present may be different than
these.
2.3.1. Temperature and Humidity Range
Temperature
Humidity
2.3.2. Suspended Particulate
2.3.3. Vibration
2.3.4. Shock
Operating
5°C to 40°C (T < 10°C/h)
Non-Operating (mech.)
-40°C to 60°C (T < 20°C/h)
Non-Operating (tape)
-40°C to 45°C (T < 20°C/h)
Operating
20 to 80% RH, no condensation
Maximum wet bulb temperature = 26°C
Non-Operating (mech.)
10 to 90% RH (RH < 30%/h)
Maximum wet bulb temperature = 26°C
Non-Operating (tape)
20 to 80% RH (RH < 30%/h)
Maximum wet bulb temperature = 26°C
Operating
Less than 150 micrograms/m
3
Based Sampling period 24 hours
Operating
Swept Sine 5 to 500 Hz
@0.25G Peak 1 Octave/min.
3 axis, 3 directions
Non-operating
Random Vibration 5 to 50 Hz
P.S.D. (Power Spectral Density)
5 to 50 Hz, 0.043 G
2
/Hz
50 to 100 Hz -36 db/oct
3 axis, 20 min.
Operating
No Data Loss
Half Sine
5 G Peak 3 ms
3 axes
*Interval 10 seconds
Non-operating
No Device Damage
Half Sine
(50 G 20 ms All faces)