- SS-HQ1 Application Notes -
Ver.1.0.0 January 7, 2005
48
Table 6.4-2 CCD Types and Linear Matrix Parameters (Reference Values)
CAT
2 (PICT1)
Byte
37
38
39
40
bit
0 to 7
0 to 7
0 to 7
0 to 7
Parameter name
RYGAIN1
BYGAIN1
RYHUE1
BYHUE1
ICX254/255AK
510H
ICX404/405AK
ICX258/259AK
760H
Type
1/3
ICX408/409AK
ICX206/207AK
510H
ICX226/227AK
ICX228/229AK
760H
Type
1/4
ICX278/279AK
3F[h] 21[h] 80[h] FF[h]
* The above linear matrix parameters are example setting determined with an emphasis on color
reproducibility for skin color in representative samples of each CCD type. Please note that they are not
intended to be adjusted to the target displayed on the vector scope.
*Use the above linear matrix parameters as reference values. In actual practice, we recommend that each
user set their own values to match the color reproducibility they desire, according to factors such as the
circuits/ICs to be connected at the rear end of the DSP, the gain settings, and the video camera screen
makeup.