24
Messages
FAILURE: Danger level – Low
Information Messages
The message number is not displayed for information messages. Check the following if a message appears in the STATUS
MESSAGE window.
WARN_22
DEVICE ERROR
Failure of the peltier B control
WARN_23
CONNECTOR DETACHED
The peltier R connector disconnected
WARN_24
CONNECTOR DETACHED
The peltier G connector disconnected
WARN_25
CONNECTOR DETACHED
The peltier B connector disconnected
WARN_26
DOUSER ERROR
Trouble with the douser operation
WARN_27
BALLAST ERROR
Failure of the ballast communication for the lamp power
WARN_28
BALLAST ERROR
Incorrect settings of the lamp S/N or the lamp power wattage
Message number
Error message
Meaning
Message number
Error message
Meaning
FAIL_01
TEMPERATURE ERROR
Temperature of the system area is too high.
FAIL_02
TEMPERATURE ERROR
Temperature of the projector head area is too high.
FAIL_03
TEMPERATURE ERROR
Temperature of the power area is too high.
FAIL_04
TEMPERATURE ERROR
Temperature of the intakes is too high.
FAIL_06
TEMPERATURE ERROR
Temperature of the optical unit area is too high.
FAIL_10
TEMPERATURE ERROR
Warning for abnormal temperature of Panel R
FAIL_11
TEMPERATURE ERROR
Warning for abnormal temperature of Panel G
FAIL_12
TEMPERATURE ERROR
Warning for abnormal temperature of Panel B
FAIL_13
TEMPERATURE ERROR
Warning for abnormal temperature of the lamp
FAIL_15
TEMPERATURE ERROR
Warning for abnormal temperature of the lamp power
FAIL_16
LENS ERROR
Failure of the zoom position adjustment to the registered setting
FAIL_17
LENS ERROR
Failure of the lens focus adjustment to the registered setting
FAIL_18
LENS ERROR
Trouble with the zoom position adjustment
FAIL_19
LENS ERROR
Trouble with the lens focus adjustment
FAIL_21
ADJUSTMENT ERROR
Abnormal in the Z-axis adjustment
FAIL_24
ADJUSTMENT ERROR
Failure of calibration for luminance deterioration
FAIL_25
DEVICE ERROR
Failure of FPGA configuration
FAIL_26
DEVICE ERROR
Trouble with the IIC circuit
FAIL_27
DEVICE ERROR
Trouble with the LVDS circuit
FAIL_28
DEVICE ERROR
Trouble with the PLL circuit
FAIL_29
DEVICE ERROR
Trouble with the PARITY circuit
FAIL_30
BALLAST ERROR
Lamp power interlocked
FAIL_34
ADJUSTMENT ERROR
Deviation of the Z-axis operation for + direction
FAIL_35
ADJUSTMENT ERROR
Deviation of the Z-axis operation for – direction
FAIL_36
DEVICE ERROR
Error of the DVI setting
Message
Meaning
DOUSER CLOSED
Douser is closed.
LAMP POWER + LIMIT
Lamp power was automatically adjusted by correcting luminance
deterioration, but the picture is not brighter.
Summary of Contents for SRX-R210
Page 15: ...15 ...