Warning System
183
App
end
ix
e
s
When an error is detected immediately after the unit is powered on, or during operation, an message
appears
(see A in the following table)
on the viewfinder screen, on an external monitor, in the subdisplay
on the right-side panel, and in the control panel display, and the tally indicator
flashes
(see
B in the following table)
to alert you to the error. In addition, warning and alarm tones are output from the
EARPHONES jack and the buzzer mounted on a circuit board inside the unit
(see C and D in the following
table)
.
Notes
• Warning tones are not output unless BEEP(PHONE)/BEEP(BOARD) >WARN in the VTR >AUDIO Setup menu
is set to HIGH or LOW.
• Alarm tones are not output unless BEEP(PHONE)/BEEP(BOARD) >ALARM in the VTR >AUDIO Setup menu
is set to HIGH or LOW.
Layout of the table of warning messages
• The operation of the tally indicator is represented by graphic symbols as follows.
: 1 flash/s
: 4 flashes/s
• The warning and alarm tones are represented by graphic symbols as follows.
: 1 beep/s
: 4 beeps/s
: Continuous beep
Warning indications/tones
Warning System
Message
Tally indicator
Warning tone
Alarm tone
A
B
C
D
Problem
Operation on the VTR module
Action to take
Message
Tally indicator
Warning tone
Alarm tone
See “Warning
messages” (page 188).
–
–
–
Problem
Operation on the VTR
module
Action to take
A warning message
condition occurred
(except “0060 LOST
LOCK” described
below).
Continues operation.
Check the warning message, and resolve the condition,
referring to the “Description” column in the table of
“Warning messages”
Message
Tally indicator
Warning tone
Alarm tone
0060 LOST LOCK
a)
b)
–
Problem
Operation on the VTR
module
Action to take
Servo lock lost during
recording.
Recording continues, but
the results may be invalid.
Turn off the power and contact a Sony service
representative.
Summary of Contents for SRW-9000
Page 206: ...Index 206 Index ...