SCD-XA9000ES
29
29
FL–
FL+
CDTL/SDTC
CDTR/SDTSW
CDTL/SDTSL
CDTL/SDTSL, CDTR/SDTSR,
CDTL/SDTC, CDTR/SDTSW
CDTR/SDTSR
SCKI, LRCK/G, BCK/G
SDATAL
SDATALS
SDATAC
SDATAR
SDATAS
SDATASW
256FS,
128FS, 64FS
LRCK, BCLK,
MDAT
SL
C
SR
SW
DATA SELECTOR
IC305
DATA SELECTOR
IC307
DATA SELECTOR
IC308
DATA SELECTOR
IC306
12
13
14
1
DIGITAL FILTER,
CURRENT PULSE,
D/A CONVERTER
IC101
12
13
14
1
DIGITAL FILTER,
CURRENT PULSE,
D/A CONVERTER
IC201
FR–
FR+
MODE_SACD
MULTI
LRCK
BCLK
MDAT
X301
11.2896MHz
SWITCHING
IC304
SCKI
LRCK/G
BCK/G
SL
SR
C
SW
SDATAL
SDATAR
•
Signal Path
: SACD PLAY
: CD PLAY (ANALOG OUT)
256FS
128FS
64FS
DATA_DF
CLK_DF
LAT_DF_A
INT_DF
LRCK/G
BCK/G
SCKI
LRCK/G
BCK/G
SCKI
CLK_DF
LAT_DF_B
INT_DF
DATA_DF
DATA_DF, CLK_DF, INIT_DF,
LAT_DF_A, LAT_DF_B,
MODE_SACD, MULTI
5-4.
BLOCK DIAGRAM – AUDIO Section (1/2) –