27
2-3. CT-287A board
Preparation
1. Remove the outside panel assembly. (Refer to
“
2-2. Outside Panel Assembly
”
.)
Procedure
1. Disconnect the coaxial cable and the flexible board from the two connectors (J7381, CN4612) on the CT-287A board.
2. Release the coaxial cable from the CT inner.
J7381
CN4612
CT inner
CT-287A board
Coaxial cable
Flexible board