156
DCC Adjust
Makes settings related to
DCC (dynamic contrast
control).
DCC Function Select
DCC
/Fix
Selects the setting method for the knee point
when the OUTPUT/DCC switch is set to CAM
with DCC on.
DCC:
Automatically adjusts the knee point to
match the luminance of the subject.
Fix:
Sets the knee point to a fixed value.
DCC D Range
400%/450%/500%/550%/
600%
Sets the dynamic range when the OUTPUT/DCC
switch is set to CAM with DCC on.
DCC Point
–99 to
±0
to +99
Sets the DCC minimum knee point.
DCC Gain
–99 to
±0
to +99
Sets the gain relative to the DCC detected value.
DCC Delay Time
–99 to
±0
to +99
Sets the DCC control speed (speed of response to
changes in the video).
DCC Peak Filter
–99 to
±0
to +99
Adjusts the response sensitivity relative to the
peaks in DCC detected values.
Genlock
Makes settings related to
genlock.
Genlock
On
/Off
Turns the genlock function on/off.
Reference
Internal/External(HD)/
External(SD)/SDI IN/CA
Displays the type of reference signal used by the
camcorder.
Auto Shading
Executes auto black
shading correction.
Auto Black Shading
Execute/Cancel
Executes auto black shading correction (execute
by selecting Execute).
Reset Black Shading
Execute/Cancel
Clears the black shading correction value
(execute by selecting Execute).
Master Gain (TMP)
–6dB/–3dB/0dB/3dB/6dB/
9dB/12dB/18dB/24dB/
30dB/36dB/42dB
Sets a temporary master gain value. (The value is
the same as the value selected with the GAIN
switch.)
APR
Makes settings related to
automatic pixel noise
reduction.
APR
Execute/Cancel
Executes the automatic pixel noise reduction
function to suppress white flecks in SLS mode
(execute by selecting Execute).
Reset
Execute/Cancel
Deletes white flecks data that were added by
execution of the APR and automatic black
balance adjustment functions (execute by
selecting Execute).
Basic Authentication
Makes settings related to
basic authentication.
User Name
(Displays the current user
name.)
Sets the user name (arbitrary name for basic
authentication). Set to “admin” by factory
default.
Password
*******
Sets the password (for basic authentication). Set
to “pxw-x500” by factory default.
Maintenance
Item
Sub-item setting
Description