Section 1
Trouble Shooting
1-1.
Self-diagnosis Function
1-1-1.
Self-diagnosis Function
If an error occurs in this unit, the self-diagnosis function starts working and a code consisting of one alphabet and a four-
digit number appears on the LCD. Classification of persons in charge, classification of faulty blocks, and details of errors
can be checked by referring to this indication of five alphanumeric characters in the self-diagnosis code table.
The history of past errors can be checked in “Usage and Diag record” on the DATA tab of the Adjust Manual.
The self-diagnosis function is also described in the operation manual.
1-1-2.
Self-diagnosis Code Table
Self-diagnosis
Code
Symptom/State
Correction
A0-000
System error by software
Ask the headquarters about correction of this error.
E10-005
Lens overheating
Exchange the lens.
E10-006
Lens overheating
Exchange the lens.
E10-007
*1
Handshake correction function does
not work well
Turn the power off and on again.
E10-008
*1
Handshake correction function does
not work well
Turn the power off and on again.
E10-009
*1
Image vibration correction during
handshake function does not work
Turn the power off and on again.
E10-00B
Temperature abnormality of the lens
Exchange the lens.
E10-101
Abnormalities in zoom initialization
of the lens
Exchange the lens.
E10-102
Abnormalities in focus initialization
of the lens and abnormalities in zoom
initialization of the lens occurred si-
multaneously
Exchange the lens.
E10-103
Abnormalities in initialization of the
lens
Exchange the lens.
E10-104
Abnormalities in initialization of the
lens
Exchange the lens.
E10-10A
Focus operation failure of the lens
Exchange the lens.
E12-001
*1
Abnormality of the variable ND fil-
ter
Turn the power off and on again.
E12-002
*1
Abnormality of the variable ND fil-
ter
Turn the power off and on again.
E40-001
Battery current value goes over the
max discharge current
Check the remaining battery power because this symptom maybe de-
pended on the remaining battery level, and confirm whether or not
the symptom is occurred after replacing the battery.
If the symptom is still occurred, IC2300 and IC3102 on the AVP-25
board, or the peripheral circuit may be faulty.
Replace the AVP-25 board.
E40-002
Battery pack temperature goes over
the specified value.
Change the battery pack or place it in a cool place.
When this error is not cleared, replace the RE-328 board and/or the
AVP-25 board.
E40-003
Error of battery authentication
Use the Sony genuine battery.
When this error is not cleared, replace the RE-328 board and/or the
AVP-25 board.
Continued
*1:
Function of this code is not provided in this unit.
PXW-FS7/PXW-FS7K
1-1
Summary of Contents for PXW-FS7
Page 1: ...SOLID STATE MEMORY CAMCORDER PXW FS7 PXW FS7K SERVICE MANUAL 1st Edition Revised 3 ...
Page 6: ......
Page 8: ......
Page 14: ......
Page 16: ......
Page 22: ......
Page 24: ......
Page 36: ......
Page 38: ......
Page 44: ...2 2 修理時の電源供給について 2 2 1 AC アダプタ 修理時の電源供給については 必ず AC アダプタを使用してください PXW FS7 PXW FS7K 2 2 ...
Page 50: ......
Page 52: ......
Page 84: ......
Page 146: ......
Page 270: ......
Page 275: ...DC 177 CN1400 C1400 J1400 1 5 6 4 3 1 2 DC 177 BOARD 1 894 230 11 DC IN PXW FS7 PXW FS7K 9 5 ...
Page 292: ......
Page 294: ......
Page 295: ......