94
IR Remote
Remote control
settings
Setting
On
/ Off
Enables/disables control from the supplied infrared remote
control.
Camera
Battery Alarm
Battery low-
voltage alarm
settings
Low BATT
5% /
10%
/ 15% / ... / 45% /
50%
Sets the remaining battery level to display a battery low-
voltage alarm (5% increments).
BATT Empty
3%
to 7%
Sets the remaining battery level to display a battery empty
alarm.
Camera DC IN
Alarm
Input voltage
alarm settings
DC Low Voltage1
11.5V
to 17.0V
Sets the voltage to display a DC IN low input voltage alarm.
DC Low Voltage2
11.0V
to 14.0V
Sets the voltage to display a DC IN insufficient input voltage
alarm.
Ext. Unit
Battery Alarm
XDCA-FS7
battery settings
Near End:Info Battery
5%
to 100%
Sets the remaining battery level to display a Info-Lithium
battery low-voltage alarm (5% increments).
End:Info Battery
0%
to 5%
Sets the remaining battery level to display a Info-Lithium
battery end alarm and to stop media access.
Near End:Sony Battery
11.5V
to 17.0V
Sets the remaining battery level to display a battery low-
voltage alarm for a non Info-Lithium battery.
End:Sony Battery
11.0V
to 11.5V
Sets the remaining battery level to display a battery end alarm
for a non Info-Lithium battery and to stop media access.
Near End:Other Battery
11.5V to 17.0V (
11.8V
)
Sets the remaining battery level to display a battery low-
voltage alarm for an Anton/Bauer battery.
End:Other Battery
11.0V
to 14.0V
Sets the remaining battery level to display a battery end alarm
for an Anton/Bauer battery and to stop media access.
Detected Battery
Displays the type of battery connected to the XDCA-FS7.
If a battery is connected to the XDCA-FS7, “Info Battery,”
“Sony Battery,” or “Other Battery” is displayed. If a DC
source is connected, “DC IN” is displayed.
If powered by a battery or DC source connected to the
camcorder, “ --- ” is displayed.
Ext. Unit DC IN
Alarm
XDCA-FS7 input
voltage alarm
settings
DC Low Voltage1
11.5V
to 17.0V
Sets the voltage to display a DC IN low input voltage alarm.
DC Low Voltage2
11.0V
to 14.0V
Sets the voltage to display a DC IN insufficient input voltage
alarm.
All Reset
Reset factory
defaults
Reset
Execute / Cancel
Resets all settings to their factory defaults.
Execute: Reset
APR
Run APR
APR
Execute / Cancel
Runs APR (Automatic Pixel Restoration) for image sensor
auto adjustment.
Execute: Run
Note
Always attach the lens cap before running APR.
Camera Config
Down-converter
output settings
HD/2K Modulation
High
/ Low
Sets the down-converter output bandwidth for conversion to
HD and 2K
System
Item
Sub-item setting
Description
Summary of Contents for PXW-FS7