Adjusting the Lens
27
P
repa
ra
ti
ons
It is necessary to adjust the flange focal length
(the distance from the lens flange to the plane of
the image along the optical axis) if the focus does
not match properly from telephoto to wide angle
during zoom operations.
Repeated adjustment is not necessary as long as
the same lens is used.
PMW-300K1
PMW-300K2
With the supplied or optional exclusive 1/2-inch
EX Mount lens, the flange focal length can be
adjusted automatically by the menu operation.
Notes
• If a subject of insufficient contrast is used, or if
the camcorder or subject moves during the
adjustment, adjustment cannot be made
properly. Once the adjustment begins, do not
touch the camcorder body or lens until it ends.
• When the Shutter is in SLS mode, be sure to set
the SLS setting to OFF before starting the
adjustment.
• Be careful that no light source, such as a lamp,
the sun, or a bright window, is in field of view
during flange focal length adjustment.
1
Set the power switch to ON.
2
Set the IRIS switch to AUTO.
3
Place a high-contrast subject, such as a
flange focal length adjustment chart,
about 3 m (10 ft.) away from the
Adjusting the Flange Focal Length
IRIS switch
ZOOM switch
Focus ring
Zoom ring
IRIS
switch
ZOOM switch
Focus ring
Zoom ring