5.
Remove the four precision screws (M2 x 4) to detach the EVF case assembly.
Precision screws
(M2 x 4)
Harness
EVF harness sheet
EVF case assembly
Precision screws
(M2 x 4)
Precision screws
(M2 x 4)
Precision screws
(M2 x 5)
Rear (cold) shoe
CN101
DR-670 board
Handle rear
cabinet assembly
6.
Install the removed parts by reversing steps of removal.
2-13-5. LCD Assembly
Preparation
1.
Remove the handle (upper) case assembly.(Refer to
“2-13-2. Control Switch Block (GZ92000)”
2.
Remove the control panel assembly. (Refer to
.)
Procedure
1.
Peel off the tape (BT).
2.
Disconnect the harnesses from the connectors CN402 and CN403 on the KSW-62 board.