1-15. Cautions on Handling the Optical Block Assembly
When handling the optical block assembly, perform grounding as described below to prevent electrostatic breakdown.
Grounding human body
Be sure to wear a grounded wrist strap (10
8
ohms or less) to discharge static electricity charged in the human body.
Note
Since static electricity charged in clothes is not discharged from the wrist strap, keep your clothes away from the optical
block assembly.
Grounding the workbench
Be sure to put the optical block assembly on a grounded earth mat (10
9
ohms or less recommended) or a copper plate.
Ground wrist strap
Optical block assembly
Earth mat
Precautions
• The optical block assembly has been precisely adjusted. Do not give impact to it due to fall or careless handling.
• Do not touch the objective lens.
• When handling the optical block assembly, hold the slide base (die-casting part). If a part of human body or another
object directly touches the circuit on the printed circuit board, it may deteriorate.
• The actuator has a strong magnet. If a magnetic substance comes close to it, the characteristics change. Contacting
a metal part such as a screwdriver with the actuator may damage the objective lens. Do not bring a magnetic
substance close to the optical block assembly.
• Be careful so that any foreign matter does not enter the clearance of the actuator cover.
PDW-HD1550
1-39
Summary of Contents for PDW-HD1550
Page 1: ...PROFESSIONAL DISC RECORDER PDW HD1550 SERVICE MANUAL 1st Edition Revised 2 ...
Page 12: ......
Page 52: ...Hold the shaded portions Keep away a screwdriver Objective lens Actuator PDW HD1550 1 40 ...
Page 54: ......
Page 90: ......
Page 102: ...Menu hierarchy M2 SERVICE SUPPORT M23 OPTION KEY STATUS INSTALL REMOVE PDW HD1550 4 12 ...
Page 207: ...4 Install the removed parts by reversing the steps of removal PDW HD1550 6 47 ...
Page 224: ......
Page 252: ......
Page 275: ......
Page 276: ...PDW HD1550 SY PDW HD1550 CN E 9 878 590 03 Sony Corporation Printed in Japan 2018 8 08 2014 ...