USO
RESTRITO
Parallel Tally Settings (Parallel Tally Menu)
657
Knob
Parameter
Adjustment
Setting values
1
Copy From Copy-from source 1 to 1024
2
Copy To
Copy-to source
1 to 1024
Ch
a
p
te
r 23
S
e
tu
p
Re
la
ti
n
g
to
Ro
u
te
r In
te
rfa
c
e
and
T
a
lly
(Ro
u
te
r/Ta
lly
)
3
Press [Execute].
Parallel Tally Settings
(Parallel Tally Menu)
For settings relating to parallel tally, use the Router/Tally
>Parallel Tally menu.
Deleting Tally Copy Settings
1
In the Router/Tally >Tally Copy menu, using any of
the following methods, select the tally copy whose
settings you want to delete.
•
Press directly on the list in the status area.
•
Press the arrow keys to scroll the reverse video
cursor.
•
Turn the knob.
Knob
Parameter
Adjustment
Setting values
1
Copy No
Tally copy setting
selection for
deletion
1 to maximum
value
2
Press [Delete].
Make the parallel port settings for output of tally
information pertaining to sources and destinations.
For each of the tally output terminal numbers, specify the
tally type, and source address or destination level and
address.
To display the Parallel Tally menu
In the Engineering Setup menu, select VF6 ‘Router/Tally’
and HF6 ‘Parallel Tally.’
The status area shows the parallel tally settings.
Making or Modifying Parallel Tally
Settings
1
In the <Device> group of the Router/Tally >Parallel
Tally menu, select DCU1 or DCU2.
2
Using any of the following methods, select the slot
number and port number.
•
Press directly on the list in the status area.
•
Press the arrow keys to scroll the reverse video
cursor.
•
Turn the knobs.
Knob
Parameter
Adjustment
Setting values
1
Slot No
Parallel tally slot
number
2 to 6
a)
2
Port No
Parallel tally port
number
1 to 54
b)
a)
When the MKS-2700 is connected, select 2 for the slot.
b)
When the MKS-2700 is connected, select a value in the range 1 to 36.
3
Press [Set].
The Set menu appears.
4
In the <Source/Destination> group, select the tally
type.
Src:
Return a tally to all sources output to the
destination.
Dest:
Return a tally to the destination outputting the
source to which a source tally is returned.
5
Set the destination address and level.
The level setting is only required when in step
4
you
selected Destination.
Summary of Contents for MVS-8000X SystemMVS-7000X System
Page 358: ...USO RESTRITO 358 Wipe Pattern List Appendix Volume 1 Enhanced Wipes Rotary Wipes ...
Page 360: ...USO RESTRITO Random Diamond DustWipes 360 1 w pe PaternLO ...
Page 362: ...USO RESTRITO 362 DME Wipe Pattern List Appendix Volume 1 Door 2D trans 3D trans ...
Page 364: ...USO RESTRITO 364 DME Wipe Pattern List Appendix Volume 1 Page turn Page roll ...
Page 377: ...USO RESTRITO Menu Tree 377 Appendix Volume 1 AUX Menu AUX button CCR Menu CCR button ...
Page 379: ...USO RESTRITO Menu Tree 379 Appendix Volume 1 DME Menu DME button ...
Page 381: ...USO RESTRITO Menu Tree 381 Appendix Volume 1 Macro Menu MCRO button ...
Page 382: ...USO RESTRITO 382 Menu Tree Appendix Volume 1 Key Frame Menu KEY FRAME button ...
Page 383: ...USO RESTRITO Menu Tree 383 Appendix Volume 1 Effect Menu EFF button ...
Page 384: ...USO RESTRITO 384 Menu Tree Appendix Volume 1 Snapshot Menu SNAPSHOT button ...
Page 385: ...USO RESTRITO Menu Tree 385 Appendix Volume 1 Shotbox Menu SHOTBOX button ...
Page 386: ...USO RESTRITO 386 Menu Tree Appendix Volume 1 File Menu FILE button ...
Page 391: ...USO RESTRITO Menu Tree 391 Appendix Volume 1 ENG SETUP button to previous pages ...
Page 413: ...USO RESTRITO MVS 8000X System MVS 7000X System SY 4 470 637 01 1 Sony Corporation 2013 ...
Page 706: ...USO RESTRITO MVS 8000X System MVS 7000X System SY 4 470 637 01 1 Sony Corporation 2013 ...