Basic Menu Operations
Ch
apt
Setting parameters
This marking on a function button indicates
that there are parameters which can be
adjusted with the knobs.
Pressing this function button assigns
parameters to the knobs.
You can set the parameter values by either
of the following methods.
• Turn the knob (1 to 5) corresponding to
the parameter, to adjust the value.
• Press the knob parameter buttons (1 to 5)
corresponding to the parameter. This
displays the numeric keypad window
allowing you to enter the desired value.
In the description of specific setting
procedures, the knob adjustment is
described, as follows.
Example:
When wipe pattern key is selected
When the [MENU] button in the device
control block is lit, you can use the trackball
and Z-ring to control the parameters.
• Move the trackball on the x-axis to
control the parameter for knob 1 or on the
y-axis to control the parameter for knob
2. Moving up or to the right increases the
parameter value, and moving down or to
the left decreases the parameter value.
• Use the Z-ring to adjust the parameter for
knob 3. Turning clockwise increases the
parameter value, and turning
counterclockwise decreases the
parameter value.
Going back to the previous menu
To return to the last displayed menu, press
the previous page button.
Returning to default state in function
groupings
1
Press the [Default Recall] button,
turning it on.
This enters the menu default recall
mode.
2
Press the VF button you want to return
to the default state.
This returns the settings within the
function grouping to the default state,
and the [Default Recall] button goes
off.
Note
The default state of the settings depends on
the setting of the initial status mode, set in
the Setup menu of system setup, as follows.
User:
The state when [Initial Status Define]
is executed.
Factory:
Factory default settings
Returning knob parameters to
default state
1
Press the [Default Recall] button,
turning it on.
This enters the menu default recall
mode.
Knob
Parameter
Adjustment
Setting values
1
Size
Pattern size
0.00 to 100.00
2
Soft
Edge softness
0.00 to 100.00
3
Density
Key density
0.00 to 100.00
Summary of Contents for MVS-6000
Page 12: ...12 Table of Contents Diagnostic Menu 393 Index 394 ...
Page 92: ...92 Basic Menu Operations Chapter 2 Menus and Control Panel ...
Page 140: ...Key Snapshots 196 Key Snapshot Operations 196 ...
Page 198: ...198 Key Snapshots Chapter 4 Keys ...
Page 220: ...220 Wipe Snapshots Chapter 5 Wipes ...
Page 254: ...254 Creating User Programmable DME Patterns Chapter 6 DME Wipes ...
Page 330: ...330 Video Process Settings Chapter 8 Color Backgrounds Copy and Swap and Other Settings ...
Page 350: ...Chapter 9 Color Corrector 350 Color Corrector Functions ...