154
Specifications
Ap
pend
ix
e
s
M08
TIMECODE
TC OUT
AUTO/GENE
AUTO
Selects the time code signal output.
AUTO: Outputs the time code generator
output during recording and outputs the
time code reader output during playback.
GENE: Outputs the time code generator
output during recording and playback.
DF/NDF
(MSW-970 only)
DF/NDF
DF
Sets DF or NDF mode.
DF: Drop frame mode
NDF: Non-drop frame mode
EXT-LK UBIT
INT/EXT
INT
Sets whether the LTC UBIT setup value locks
to an INT or an EXT source when the time
code is locked to an external source.
INT: Internal lock
EXT: External lock
LTC UBIT
FIX/TIME
FIX
Sets the data to be recorded in UBIT of LTC.
FIX: Records the data that is set by the user.
TIME: Records the present time.
VITC UBIT
FIX/TIME
FIX
Sets the data to be recorded in UBIT of VITC.
FIX: Records the data that is set by the user.
TIME: Records the present time.
WATCH AUTO ADJ
OFF/ON
ON
Turns the automatic time correction function
of the built-in clock on/off . With ON, the time
of the built-in clock matches with the time
data of the user bits of an external time code.
UBIT GROUP ID
000/101
000
Selects the UBIT GROUP ID.
VITC INS LINE 1
12 to 19 H
(MSW-970)
16H
Selects the line into which VITC is to be
inserted.
9 to 22 H
(MSW-970P)
19H
VITC INS LINE 2
12 to 19 H
(MSW-970)
18H
Selects the line into which VITC is to be
inserted.
9 to 22 H
(MSW-970P)
21H
M09
VTR MODE
REC TALLY BLINK
OFF/ON
ON
Turns the tally illumination control on/off in the
event of BATTERY BEFORE END/DISC
BEFORE END.
REC START BEEP
OFF/ON
OFF
Turns on/off the alarm sound at REC START/
STOP.
LCD DISPLAY
HOLD
TIMER/OFF/CONT
TIMER
Sets the time code (TC) display after power-
off as follows.
TIMER: The TC display turns off after the
elapse of the time set by the LCD HOLD
TIMER below.
OFF: Not displayed.
CONT: Displayed.
LCD HOLD TIMER
1H/3H/8H
1H
Sets the duration of time after which the TC
display is to be turned off after power-off,
when LCD DISPLAY HOLD is set to TIMER
(H: hours).
REC VIDEO RATE
50M/40M/30M
50M
Sets the recording bit rate.
STBY OFF TIMER
OFF/5MIN/10MIN/
30MIN/60MIN
60MIN
Sets the length of time for the stand-by off
timer.
STOP KEY FREEZE OFF/FRAME/
FIELD
OFF
Selects the freeze function.