Appendix
Appendix
A-17
000H: STEREO REC
001H: MONORAL REC
0FFH: sense
Note
Use this command while the MD deck is
stopped.
RETURN command: 0BCH
KILL LOCAL MODE SELECT
Command: 03DH
Function : Selects the Kill Local function mode.
DATA: 1
DATA1
000H: KILL ALMOST
001H: KILL ALL
0FFH: sense
Note
Use this command while the MD deck is
stopped.
RETURN command: 0BDH
SWITCH ENABLE SELECT (KILL
LOCAL function)
Command: 04CH
Function : Enables/disables operation buttons on the
front panel of the deck. Select the DISABLE
(KILL LOCAL function) when you want to
prevent misoperation. Also, the deck provides
the KILL LOCAL function in the parallel
remote control mode, and the function is active
if either RS-232C control or parallel control is
turned on.
DATA: 1
DATA1
000H: DISABLE
001H: ENABLE
0FFH: SWITCH ENABLE SENSE
RETURN command: 0CCH
MECHA STATUS SENSE
Command: 050H
Function : Demands to output the status information
of mechanism.
For the description of statuses, see “MECHA
STATUS RETURN”: 0D0H.
DATA: None
RETURN command: 0D0H
TRACK No. STATUS SENSE
Command: 055H
Function : Demands to output current track number.
DATA: None
RETURN command: 0D5H
DISC STATUS SENSE
Command: 056H
Function : Demands to output information including a
disc is inserted or not, if it is premastered or
recordable disc, and if the record-protect slot is
open or not.
DATA: None
RETURN command: 0D6H
DISC NAME SENSE
Command: 057H
Function : Demands to output the disc title (character
information).
DATA: 1, or none (in this case, DATA=000H)
DATA1
000H: 1 to 8 characters from the beginning
001H: 9 to 16 characters from the beginning
002H: 17 to 24 characters from the beginning
:
:
:
:
009H: 73 to 80 characters from the beginning
00AH: 81 to 88 characters from the
beginning
00BH: 89 to 96 characters from the
beginning
00CH: 97 to 100 characters from the
beginning
RETURN command: 0D7H
CURRENT TRACK TIME SENSE
Command: 058H
Function : Demands to output the elapsed thme of a
track in PLAY or PAUSE mode. The “minute/
second” and “minute/second/sub-second” can be
selected.
Note
The MD format of the deck does not contain the
time code. For this reason, the set does not
support the slave operation by means of external
cycle or phase modulation.