4-5. Temperature Compensation Offset Adjustment
Save the temperature data at that time in the non-volatile memory as
25 ˚C reference data.
Note :
1. Usually, do not perform this adjustment.
2. Perform this adjustment in an ambient temperature of 22 ˚C to 28
˚C. Perform it immediately after the power is turned on when the
internal temperature of the unit is the same as the ambient tem-
perature.
3. When D101 has been replaced, perform this adjustment after the
temperature of this part has become the ambient temperature.
Adjusting Method :
1. Rotate the AMS knob and display “TEMP ADJUST”.
2. Press the ENTER/YES button and select the “TEMP ADJUST”
mode.
3. “TEMP =
” and the current temperature data will be displayed.
4. To save the data, press the ENTER/YES button.
When not saving the data, press the EDIT/NO button.
5. When the ENTER/YES button is pressed, “TEMP =
SAVE”
will be displayed for some time, followed by “TEMP ADJUST”.
When the EDIT/NO button is pressed, “TEMP ADJUST” will be
displayed.
Specifications :
The “TEMP =
” should be within “E0 - EF”, “F0 - FF”, “00 - 0F”,
“10 - 1F” and “20 - 2F”.
4-6. Laser Power Adjustment
Connection :
Adjusting Method :
1. Set the laser power meter on the objective lens of the optical pickup.
(When it cannot be set properly, press the
0
button or
)
but-
ton and move the optical pickup.)
Connect the digital volt meter to TP (IOP) and TP (I+5V).
2. Rotate the AMS knob and display “LDPWRADJUST”.
(Laser power : For adjustment)
3. Press the ENTER/YES button twice and display “LD $ 4B = 3.5
mW”.
4. Adjust RV102 of the BD board so that the reading of the laser
power meter becomes 3.4
mW.
5. Press the ENTER/YES button and display “LD $ 96 = 7.0 mW”.
(Laser power:MO reading)
6. Check that the laser power meter and digital voltmeter readings
satisfy the specified value.
Specification :
Laser power meter reading : 7.0 ± 0.3 mW
Digital voltmeter reading : Optical pickup displayed value ± 10%
(Optical pickup label)
+0.1
–0
Laser power
meter
Optical pick-up
objective lens
Digital voltmeter
KMS
210A
27X40
B0825
n
lop = 82.5 mA in this case
lop (mA) = Digital voltmeter reading (mV)/ 1 (
Ω
)
7. Press the ENTER/YES button and display “LD $ 0F = 0.7 mW”.
(Laser power: MO reading)
8. Check that the laser power meter at this time satisfies the speci-
fied value.
Specification :
Laser power meter reading : 0.70 ± 0.1 mW
9. Press the EDIT/NO button and display “LDPWR ADJUST’, and
stop laser emission.
(The EDIT/NO button is effective at all times to stop the laser
emission.)
BD board
TP (I + 5V)
TP (IOP)
Summary of Contents for MDS-B5
Page 2: ... 2 ...
Page 5: ... 5 SECTION 1 GENERAL This section is extracted from instruction manual ...
Page 6: ... 6 ...
Page 7: ... 7 ...
Page 8: ... 8 ...
Page 9: ... 9 ...
Page 10: ... 10 ...
Page 11: ... 11 ...
Page 12: ... 12 ...
Page 13: ... 13 ...
Page 14: ... 14 ...
Page 15: ... 15 ...
Page 16: ... 16 ...
Page 17: ... 17 ...
Page 18: ... 18 ...
Page 19: ... 19 ...
Page 20: ... 20 ...
Page 21: ... 21 ...
Page 22: ... 22 ...
Page 23: ... 23 ...
Page 24: ... 24 ...
Page 25: ... 25 ...
Page 26: ... 26 ...
Page 27: ... 27 ...
Page 28: ... 28 ...
Page 29: ... 29 ...
Page 30: ... 30 ...
Page 31: ... 31 ...
Page 32: ... 32 ...
Page 49: ......
Page 50: ......
Page 51: ......
Page 52: ......
Page 53: ......
Page 54: ......
Page 55: ......
Page 56: ......
Page 57: ......
Page 58: ......