1-1
HVR-M25J/M25U/M25N/M25E/M25P/M25C
ENGLISH
ENGLISH
1. SERVICE NOTE
1-2-1. Self-diagnosis Function
When problems occur while the unit is operating, the self-diagnosis
function starts working, and displays on the LCD monitor what to
do.
Details of the self-diagnosis functions are provided in the Instruction
manual.
1-2-2. Self-diagnosis Display
When problems occur while the unit is operating, the time code of
the LCD monitor shows a 4-digit display consisting of an alphabet
and numbers, which blinks at 3.2 Hz. This 5-character display
indicates the “repaired by:”, “block” in which the problem occurred,
and “detailed code” of the problem.
1 1
3 1
C
Repaired by:
Refer to
“1-2-3. Self-diagnosis Code Table”.
Indicates the appropriate
step to be taken.
E.g.
31 ....Reload the tape.
32 ....Turn on power again.
Block
Detailed Code
Blinks at 3.2Hz
C : Corrected by customer
H : Corrected by dealer
E : Corrected by service
engineer
LCD monitor
C : 3 1 : 1 1
1-2. SELF-DIAGNOSIS FUNCTION
1-1. PRECAUTION ON REPLACING THE VD-036 BOARD
Set S4602 of the VD-036 board to the following position.
Switch setting
S4602 ...................................... 60i (HVR-M25J/M25U/M25N)/50i (HVR-M25E/M25P/M25C)
S4602
60i
t
50i
VD-036 BOARD (SIDE B)