75
[Advanced] appears when [USB 7] is set to [System
Control], or when [RS-232C] is set to [System
Control] or [Control Monitor].
The [Advanced] settings screen for system control
appears.
2
Select the transmission speed.
For USB port 7, the transmission speed is fixed at
115200 bps.
For the RS-232C connector, you can select from
9600 bps, 19200 bps, 38400 bps, 57600 bps, and
115200 bps for the transmission speed.
The default setting is [9600 bps].
3
Select the mode to use in [Protocol Mode], select
[Apply], and then press the ENTER button.
You can select from [HVO-1000MD],
[HVO-3000MT], and [HVO-3300MT].
The default setting is [HVO-1000MD].
Depending on the selected mode, protocol command
compatibility with the corresponding model is
enabled.
• The [Protocol Mode] setting is only used when
controls are performed using commands via USB
port 7 or the RS-232C connector. It does not affect
“close folder” or playback/recording stop
operations on the unit, remote control unit, or touch
panel menu screen.
• The [Protocol Mode] setting cannot be configured
differently for USB port 7 and the RS-232C
connector. The mode selected last will overwrite
the previous setting.
The configurations are saved, and the [Control] tab
appears again.
To configure monitor control settings
Configure the image output port and input signal settings
when outputting images from a device (e.g., endoscopic)
or from the unit onto a monitor.
1
Select [Advanced] for [Control Monitor], and press
the ENTER button.
The [Advanced] settings screen for monitor control
appears.
2
Configure each setting, select [Apply] and press the
ENTER button.
[Device IN Port]
Select the input port to use on the monitor side when
outputting images from a device (e.g., endoscopic).
You can select from [PORT A] and [PORT B].
The default setting is [PORT A].
[Device IN Signal]
Select the signal that will be input to the monitor
when outputting images from a device (e.g.,
endoscopic).
You can select from [SDI 1], [SDI 2], [DVI-D 1],
[DVI-D 2], [VIDEO], and [S VIDEO].
The default setting is [SDI 1].
[Recorder IN Port]
Select the input port to use on the monitor side when
outputting images from the unit.
You can select from [PORT A] and [PORT B].
The default setting is [PORT B].
[Recorder IN Signal]
Select the signal that will be input to the monitor
when outputting images from the unit.
You can select from [SDI 1], [SDI 2], [DVI-D 1],
[DVI-D 2], [VIDEO], and [S VIDEO].
The default setting is [SDI 2].
The same input signal cannot be configured for both
[Device IN Signal] and [Recorder IN Signal] at the
same time.
[Contact Switch] Tab
Configure these settings when you want to control the
unit via contact switch devices connected to the contact
switch connectors on the rear panel of the unit.
[Contact Switch 1] to [Contact Switch 3]
Specify what will be controlled via the contact switch
device for each contact switch.
The procedure for configuring [Contact Switch 1] to
[Contact Switch 3] is the same.
The default setting is [Not Used].
[Not Used]
Disable use of the contact switch device.
[Record Video/Pause]
Control pause and resume functions while recording
videos.
[Record Still]
Capture still images.
[Audio On/Off]
Enable or disable audio output.
Tips
Tip
Summary of Contents for HVO-3300MT
Page 99: ......