2-4-2.
CCD Unit (HSC100R/100RF)
Note
Do not replace the CCD unit with the power turned on.
Before replacing the CCD unit, be sure to turn off the power switch and disconnect the TRIAX/optical fiber cable or
the cable connected to the DC IN connector.
Preparation
1.
Remove the outside panel assembly.
• HSC300R/100R: Refer to
“2-2-1. Outside Panel Assembly (TRIAX)”
• HSC300RF/100RF: Refer to
“2-3-1. Outside Panel Assembly (Fiber)”
Procedure
1.
Disconnect the two flexible flat cables from the two connectors (CN001, CN003) on the TG-285 board.
Note
Be careful not to bend the flexible card wire. This shortens the wire life.
2.
Remove the four screws to detach the front assembly.
B3 x 10
B3 x 10
Front assembly
TG-285 board
CN001
Flexible flat cables
CN003
3.
Loosen the setscrew to detach the filter select knob.
HSC300RF/HSC100RF/HSC300R/HSC100R
2-11