Warning/Error Messages
158
Ap
pend
ix
es
When an error message appears
Check the message and eliminate the cause of the
error.
If the error involved the tape transport
mechanisms (SLACK-35, etc.), contact a Sony
service representative.
For other errors, power the unit off and on again.
If the same error message appears again when the
unit is powered on, contact a Sony service
representative.
To close the error message popup window
Press the HOME button or the BACK button on
the control panel.
If you press the HOME button, an error code
appears in the operation status and warnings
section of the control panel display
If you press the BACK button, the same error
code appears in the operation status and warnings
section of the display when you move back as far
as the HOME screen.
The error code remains visible until the cause of
the error is eliminated.
Tape protection mode
To protect the tape and the mechanical parts of
the SRW-9000, the servo control system
automatically stops tape transport and the drum
motor and enters tape protection mode when an
error occurs.
Cassettes may not be inserted or ejected while the
unit is in tape protection mode.
Error messages
Refer to the Maintenance Manual for more detailed
information about the content of error messages, and
about errors not listed here.
Example:
Popup window displaying error
message “VTR: 007F HUMID ERROR”
(condensation detected)
There is one current error.
There are two current warnings
.
To view the other messages, turn the SELECT/
ENTER dial on the control panel.
Code Message
Description
0010
FAN STOP
A cooling fan stopped.
0011
0012
0014
DC VOLTAGE
DOWN
Decline in power
supply voltage was
detected.
0050
NO REC RF
Recording error
occurred. Could not
detect RF signal.
0057
EQ NVRAM
SUM ERROR
EQ NVRAM operating
error was detected.
0058
CONT REC NG
TC
Continuous recording
error was detected.
005A CONT REC NG
SV
Continuous recording
error was detected.
005C TIMER REC NG Timer Rec error was
detected.
005F
EQ TEMP NG
Abnormal EQ
temperature was
detected.
0060
SLACK-10
Drum drive voltage
error was detected.
0061
SLACK-11
Drum FG error was
detected.
0062
SLACK-12
Drum PG error was
detected.
0063
SLACK-35
S reel rotation was
detected in stop mode.
0064
SLACK-45
Abnormal ratio of T
reel speed to capstan
speed was detected
during fast forward.
0065
SLACK-75
It is necessary to check
the cassette.
0066
SLACK-70
Servo NVRAM
communications error
was detected.
0067
SLACK-71
System control
initialization command
error was detected.
Summary of Contents for HKSR-9003