4-2 TC Setup Menu
4-2 TC Setup Menu
The TC (timecode) Setup menu allows you to make
settings related to timecode.
In the Settings column of the following table:
• Factory default settings are underlined.
• Square brackets indicate settings as displayed in setting
windows
(see the figure for step
3
.
Item
Settings
TIMER SEL
Selects the type of time data to use.
CTL [CTL Timer]: Display the tape running time in Hours:Minutes:Seconds
format.
TC [Time Code]: Display timecode.
UBIT [User Bit]: Display user bits.
TIMER RESET
Resets the internal timecode generator. Time data is displayed as 00:00:00:00
(timecode) or 00 00 00 00 (user bits).
Notes
• The values read by the timecode reader cannot be reset.
• The timecode generator cannot be reset when it is locked to external timecode
or to the values read by the internal timecode reader.
TIMER PRESET
Selects the type of time data to preset to an arbitrary value.
TCG TC: Timecode generated by the timecode generator
TCG UBIT: User bits generated by the timecode generator
CTL: CTL signal count
TCR SEL
Selects the type of timecode which you want the internal timecode reader to
read during playback.
AUTO [AUTO]: Read VITC when the playback speed is less than ±1/2 times
normal speed, and LTC when the playback speed is more than ±1/2 times
normal speed.
LTC [LTC]: Read LTC.
VITC [VITC]: Read VITC.
TCG MODE
Selects the type of timecode to which the internal timecode generator
synchronizes.
PRST [Preset]: Synchronize to a preset value. You can use the TIMER PRESET
item to preset the initial value of the timecode generated by the internal
timecode generator.
RGN [Regen]: Synchronize to the timecode selected in the following item
REGENE SOURCE (regenerate).
REGENE SOURCE
Selects the timecode to be regenerated by the internal timecode generator.
INT L [Internal LTC]: Timecode recorded in the longitudinal direction on the tape
EXT L [External LTC]: Timecode input to the TC IN connector
SDI-L [SDI LTC]: Video signal LTC time data input to the HD SDI IN A/B
connectors
SDI V [SDI VITC]: Video signal VITC input to the HD SDI IN A/B connectors
RUN MODE
Selects the timecode generator run mode.
F RUN [Free Run]: Timecode advances without pause from the time that the
system is powered on.
R RUN [Rec Run]: Timecode advances only during recording.