5-9
4. HALL Adjustment
For detecting the position of the lens iris, adjust the hall AMP gain
and offset.
Subject
Not required
Measurement Point
DDS display data of LCD or TV
Measuring Instrument
monitor (Note 3)
Adjustment Page
F
Adjustment Address
1E, 1F
Specified Value
15 to 19 during IRIS OPEN (Note 1)
88 to 8C during IRIS CLOSE
(Note 2)
Note 1:
Select page: 6, address: 01, set data: 01, and press the PAUSE
button of the adjustment remote commander.
Note 2:
Select page: 6, address: 01, set data: 03, and press the PAUSE
button of the adjustment remote commander.
Note 3:
DDS display data of LCD or TV monitor.
CA 00 00XX
Object data
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 11, set data: 12, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: 6, address: 00, and set data: 01.
4)
Select page: 6, address: 04, and set data: 03.
5)
Select page: 6, address: 01, set data: 03, and press the PAUSE
button.
6)
Select page: F, address: 1F, set data: 80, and press the PAUSE
button.
7)
Select page: F, address: 1E, set data: 40, and press the PAUSE
button.
8)
Read the DDS display data (the bottom two digits of the display
data at the bottom right of the LCD display or the TV monitor),
and this data is named W
2
.
9)
Select page: F, address: 1E, set data: 30, and press the PAUSE
button.
10) Read the DDS display data, and this data is named W
1
.
11) Select page: 6, address: 01, set data: 01, and press the PAUSE
button.
12) Read the DDS display data, and this data is named K
1
.
13) Select page: F, address: 1E, set data: 40, and press the PAUSE
button.
14) Read the DDS display data, and this data is named K
2
.
15) Convert W
1
, W
2
, K
1
, K
2
, to decimal notation, and obtain W
1
' ,
W
2
' , K
1
' , K
2
'. (Refer to “Hexadecimal-decimal Conversion
Table”. of “5-4. Service mode”.)
16) Calculate X
1
' using the following equations (decimal notation
calculation).
A'= W
2
' + K
1
' – W
1
' – K
2
' ....................................... Equation 1
B'= W
1
' – K
1
' ......................................................... Equation 2
X
1
'=[1840 + (48
×
A') – (16
×
B')]/A' ................... Equation 3
17) Convert X
1
' to hexadecimal notation, and obtain X
1
.
(Round off to one decimal place)
18) Select page: F, address: 1E, set data: X
1
, and press the PAUSE
button.
19) Select page: 6, address: 01, and set data: 01, and press the
PAUSE button.
20) Select page: F, address: 1F, change the data and adjust the DDS
display data to “17”.
21) Press the PAUSE button of the adjustment remote commander.
22) Select page: 6, address: 01, and set data: 03, and press the
PAUSE button.
23) Read the DDS display data, and this data is named W
0
. If W
0
lies within the “88” to “8C” range, perform “Processing after
completing adjustments”. If it is lies outside the range, perform
the following adjustments.
24) Convert W
0
to decimal notation, and obtain W
0
'.
25) Calculate X
2
' using the following equations (decimal notation
calculation).
C'= W
0
– B'–23 ...................................................... Equation 4
X
2
'=[(115 – B')
×
(X
1
' – 48) + (48
×
C')]/C' .......... Equation 5
(X
1
' and B' are values obtained from equations 2) and 3) )
26) Convert X
2
' to hexadecimal notation, and obtain X
2
. (Round
off to one decimal place)
27) Select page: F, address: 1E, set data: X
2
, and press the PAUSE
button.
28) Select page: 6, address: 01, set data: 03, and press the PAUSE
button.
29) Select page: F, address: 1F, change the data and adjust the DDS
display data to “8A”.
30) Press the PAUSE button of the adjustment remote commander.
31) Select page: 6, address: 01, set data: 01, and press the PAUSE
button.
32) Check the DDS display data lies within the “15” to “19” range.
Processing after Completing Adjustments
1)
Select page: D, address: 11, and set data: 10, and press the
PAUSE button.
2)
Select page: 0, address: 01, and set data: 00.
3)
Select page: 6, address: 01, and set data: 00, and press the
PAUSE button.
4)
Select page: 6, address: 04, and set data: 00.
5)
Select page: 6, address: 00, and set data: 00.
Summary of Contents for Handycam Vision DCR-TRV5
Page 10: ...1 2 ...
Page 11: ...1 3 ...
Page 12: ...1 4 ...
Page 13: ...1 5 ...
Page 14: ...1 6 ...
Page 15: ...1 7 ...
Page 16: ...1 8 ...
Page 17: ...1 9 ...
Page 18: ...1 10 ...
Page 19: ...1 11 ...
Page 20: ...1 12 ...
Page 21: ...1 13 ...
Page 22: ...1 14 ...
Page 23: ...1 15 ...
Page 24: ...1 16 ...
Page 25: ...1 17 ...
Page 26: ...1 18 ...
Page 27: ...1 19 ...
Page 28: ...1 20 ...
Page 29: ...1 21 ...
Page 30: ...1 22 ...
Page 31: ...1 23 ...
Page 32: ...1 24 ...
Page 33: ...1 25 ...
Page 34: ...1 26 ...
Page 35: ...1 27 ...
Page 36: ...1 28 ...
Page 37: ...1 29E ...
Page 45: ...DCR TRV5 TRV5E SECTION 3 BLOCK DIAGRAMS 3 1 OVERALL BLOCK DIAGRAM 1 3 1 3 2 3 3 3 4 ...
Page 46: ...DCR TRV5 TRV5E 3 2 OVERALL BLOCK DIAGRAM 2 3 6 3 7 3 8 DCR TRV5 TRV5E ...
Page 47: ...DCR TRV5 TRV5E 3 3 POWER BLOCK DIAGRAM 3 9 3 10 3 11 3 12 3 13E ...
Page 71: ...DCR TRV5 TRV5E 4 75 4 76 4 77 AUDIO PROCESSOR AU 204 ...
Page 73: ...DCR TRV5 TRV5E 4 81 4 82 AUDIO PROCESS IR TRANSMMITER MA 330 ...
Page 107: ...ARRANGEMENT DIAGRAM FOR ADJUSTMENT PARTS VC 207 board SIDE A VC 207 board SIDE B 5 26 ...
Page 131: ...ARRANGEMENT DIAGRAM FOR ADJUSTMENT PARTS VC 207 board SIDE A VC 207 board SIDE B 5 52 ...