5-22
5. HALL Adjustment
(DCR-TRV20/TRV20E)
For detecting the position of the lens iris and ND filter, adjust each
AMP gain and offset.
Subject
Not required
Measurement Point
Display data of page 1 (Note1)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
17, 18, 19, 1A, 1B, 1C
Specified Value
When the data of page: 6, address: 01
is “01”: 15 to 19 (Note2)
When the data of page: 6, address: 01
is “03”: 87 to 8B (Note2)
When the data of page: 6, address: 01
is “69”: 87 to 8B (Note2)
When the data of page: 6, address: 01
is “6B”: 15 to 19 (Note2)
Note1:
Displayed data of page 1 of the adjustment remote commander.
1 : XX : XX
IRIS display data
ND display data
Note2:
The PAUSE button of the Adjustment remote commander must be
pressed.
Switch setting:
POWER .................................................................. CAMERA
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 6, address: 94, and set data: 17.
3)
Select page: 6, address: 95, and set data: 89.
4)
Select page: 6, address: 01, set data: 6D, and press the PAUSE
button of the adjustment remote commander. (The HALL
adjustment is performed and the adjustment data is stored in
page: F, address: 17 to 1C.)
5)
Select page: 6, address: 02, and check that the data is “01”.
6)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button.
Checking method:
1)
Select page: 6, address: 04, and set data: 03.
2)
Select page: 6, address: 01, set data: 01, and press the PAUSE
button.
3)
Select page: 1, and check that the IRIS display data (Note1)
satisfies the specified value.
4)
Select page: 6, address: 01, set data: 03, and press the PAUSE
button.
5)
Select page: 1, and check that the IRIS display data (Note1)
satisfies the specified value.
6)
Select page: 6, address: 01, set data: 69, and press the PAUSE
button.
7)
Select page: 1, and check that the ND display data (Note1)
satisfies the specified value.
8)
Select page: 6, address: 01, set data: 6B, and press the PAUSE
button.
9)
Select page: 1, and check that the ND display data (Note1)
satisfies the specified value.
Processing after Completing Adjustments:
1)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button.
2)
Select page: 6, address: 04, and set data: 00.
3)
Select page: 6, address: 94, and set data: 00.
4)
Select page: 6, address: 95, and set data: 00.
5)
Select page: 0, address: 01, and set data: 00.
6. MR Adjustment
(DCR-TRV20/TRV20E)
The MR (Magnet resistor) adjustment of the inner focus lens is
carried out automatically. In whichever case, the focus will be
deviated during auto focusing/manual focusing.
Subject
Not required
Measurement Point
Adjustment remote commander
Measuring Instrument
Adjustment Page
F
Adjustment Address
50 to 59, 62
Specified Value
40 to C0 (Address: 50)
40 to C0 (Address: 51)
03 to 78 (Address: 52, 54, 56, 58)
88 to F8 (Address: 53, 55, 57, 59)
Note:
Make the lens horizontal and perform this adjustment.
Switch setting:
POWER .................................................................. CAMERA
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 6, address: 01, set data: BD, and press the PAUSE
button of the adjustment remote commander. (The MR
adjustment is performed and the adjustment data is stored in
page: F, address: 50 to 59, 62.)
3)
Select page: 6, address: 02, and check that the data is “01”.
4)
Select page: F, address: 50, and check that the data satisfies the
specified value.
5)
Select page: F, address: 51, and check that the data satisfies the
specified value.
6)
Select page: F, address: 52, 54, 56 and 58, and check that the
data satisfies the specified value.
7)
Select page: F, address: 53, 55, 57 and 59, and check that the
data satisfies the specified value.
Processing after Completing Adjustments:
1)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button.
2)
Select page: 0, address: 01, set data: 00.
3)
Turn off the power and turn on again.
4)
Perform “Flange Back Adjustment”.
Summary of Contents for Handycam DCR-TRV11
Page 12: ...1 2 ...
Page 13: ...1 3 ...
Page 14: ...1 4 ...
Page 15: ...1 5 ...
Page 16: ...1 6 ...
Page 17: ...1 7 ...
Page 18: ...1 8 ...
Page 19: ...1 9 ...
Page 20: ...1 10 ...
Page 21: ...1 11 ...
Page 22: ...1 12 ...
Page 23: ...1 13 ...
Page 24: ...1 14 ...
Page 25: ...1 15 ...
Page 26: ...1 16 ...
Page 27: ...1 17 ...
Page 28: ...1 18 ...
Page 29: ...1 19 ...
Page 30: ...1 20 ...
Page 31: ...1 21 ...
Page 32: ...1 22 ...
Page 33: ...1 23 ...
Page 34: ...1 24 ...
Page 35: ...1 25 ...
Page 36: ...1 26 ...
Page 37: ...1 27 ...
Page 38: ...1 28 ...
Page 39: ...1 29 ...
Page 40: ...1 30 ...
Page 41: ...1 31 ...
Page 42: ...1 32 ...
Page 43: ...1 33 ...
Page 44: ...1 34 ...
Page 45: ...1 35 ...
Page 46: ...1 36 ...
Page 47: ...1 37 ...
Page 48: ...1 38 ...
Page 49: ...1 39 ...
Page 50: ...1 40 ...
Page 51: ...1 41 ...
Page 52: ...1 42 ...
Page 53: ...1 43 ...
Page 54: ...1 44 ...
Page 55: ...1 45 ...
Page 56: ...1 46 ...
Page 57: ...1 47 ...
Page 58: ...1 48E ...
Page 85: ...DCR TRV6 TRV6E TRV11 TRV11E TRV20 TRV20E 4 9 4 10 CCD IMAGER CD 252 1 677 549 ...