6-24
HVR-Z5C/Z5E/Z5J/Z5N/Z5P/Z5U
1-3.
CAMERA SYSTEM ADJUSTMENTS
Before perform the camera system adjustments, check that the
specified values of “VIDEO SYSTEM ADJUSTMENTS” are sat-
isfied. (Except Origin Oscillation Check”)
Check that the data of page: 0, address: 10 is “00”.
If not, select page: 0, address: 10, and set the data “00”.
1-3-1.
Camera System Adjustments
1.
Origin Oscillation Check (VC-543 board)
Check the frequency of the clock for synchronization.
If deviated, the synchronization will be disrupted and the color
will become inconsistent.
Subject
Not required
Measurement Point
R1414 (CHCK) on VC-543 board
Measuring Instrument
Frequency counter
Specified value
f = 41538461
±
835 Hz (NTSC)
f = 41580000
±
835 Hz (PAL)
Switch setting
1) POWER ......................................................... CAMERA mode
Checking method:
1) Check that the frequency (f) satisfies the specified value.
Fig. 6-1-5
IC1401
R1414
VC-543 BOARD (SIDE A)
IC1601
2.
Coaxial Harness Connecting Check
RadarW
RadarW
RadarW
RadarW
RadarW
Check if the coaxial harness of CMOS is connected correctly.
Subject
Not required
Measurement Point
Measuring Instrument
Adjusting remote commander
Adjustment Page
6
Adjustment Address
D1 to D6
Specified value
Data of page: 6, address: D0 is “07”
Note 1:
Check that the data of page: 6, address: 02 is “00”
If not, select page: 6, address: 01, set data: 00, and press
the PAUSE (Write) button.
Switch setting
1) POWER ......................................................... CAMERA mode
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
07
Check the data is “04”.
3
0
10
09
4
E
90
10
(9E)
5
E
80
00
(9E)
6
0
10
00
7
6
01
EB
Press PAUSE (Write)
button.(Note 2)
8
6
02
Check the data changes to
“01”.
9
6
D0
Check the data is “07”.
(Note 3)
Note 2:
The adjustment data will be automatically input to page:
6, address: D1 to D6.
Note 3:
For the error codes of bit 0 to bit 2 of data of page: 6,
address: D0, see the following table.
Bit value of data of
Error contents
page: 6,
address: D0
Bit
Function
When bit value = 0 When bit value = 1
0
R
Error exists
No error
1
G
Error exists
No error
2
B
Error exists
No error
Example: If an error exists in G, data is “05”
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
0
10
09
3
E
90
00
(9E)
4
E
80
70
(9E)
5
0
10
00
6
0
01
00