background image

1-5 (E)

DEP-100

Communication Connector

7

MOUSE

D-sub 9-pin connector (RS-232C interface)
Mouse control

8

ISR

D-sub 25-pin connector (RS-232C interface)
For ISR (Interactive Status Reporting)

9

REMOTE-OUT

D-sub 9-pin connector (RS-422A interface)
Remote control

!/

REMOTE-IN

D-sub 9-pin connector (RS-422A interface)
Remote control

1-5. Input and Output Signal of Connector

Summary of Contents for DEP-100

Page 1: ...DEP 100 DIGITAL EFFECTS PROCESSOR INSTALLATION MANUAL 1st Edition Serial No 10001 and Higher ...

Page 2: ...lessure n effectuer que les réparations indiquées dans le mode d emploi à moins d être qualifié pour en effectuer d autres Pour toute réparation faire appel à une personne compétente uniquement For the U S A Attention when the product is installed in Rack 1 Prevention against overloading of branch circuit When this product is installed in a rack and is supplied power from an outlet on the rack ple...

Page 3: ...tion Space 1 2 E 1 4 Matching Connectors and Cables 1 3 E 1 5 Input and Output Signal of Connector 1 4 E 1 6 Switch Setting on Connector Panel 1 7 E 1 7 Switch Setting on Board 1 7 E 1 8 Rack Mounting 1 8 E 2 Service Overview 2 1 Cleaning of Air Filter 2 1 E 2 2 Periodic Replacement 2 1 E 2 3 Information of LEDs on Board 2 2 E 2 4 ISR 2 3 E 2 4 1 Functions Overview 2 3 E 2 4 2 Usage of ISR Functio...

Page 4: ...for peripheral equipment connections etc Section 2 Service Overview Explains the cleaning and summary of ISR Related manual Besides this installation manual the following manuals are available for the DEP 100 Operation Manual Supplied with the DEP 100 This manual explains the overview of the DEP 100 and the system configuration examples Maintenance Manual Not supplied with the DEP 100 This manual ...

Page 5: ...imum 20 A at 100 V maximum 40 A at 240 V the capacity of the AC power must be adequate with the inrush current of maxi mum 20 A at 100 V maximum 40 A at 240 V If the capacity of the AC power is not the adequately large the breaker of the AC power at the supply side will operate or the DEP 100 will abnormal operate 1 2 2 Power Cord w To avoid a fire or an electric shock be sure to use the designate...

Page 6: ...tion of air in the place where the DEP 100 is installed The rear side of the DEP 100 should be at least 20 cm away from walls for ventilation and maintenance 1 3 External Dimensions and Installation Space 866 2 424 450 304 8 83 7 66 57 2 132 4 3U 14 5 44 254 101 6 482 465 424 Front view Right side view Top view Front panel Unit mm Mass 13 5 kg ...

Page 7: ...UT DIGITAL I O BNC 75 Z male 1 560 069 11 PROGRAM OUT 5C 2V cable 1 DSK INPUT SDI INPUT MOUSE 9 pin serial mouse 2 ISR D sub 25 pin male 1 566 356 11 Solderless type 1 564 747 11 Solder type GPI BNC 75 Z male 1 560 069 11 EFFECT KEY ON KEY OFF REMOTE OUT D sub 9 pin male 1 560 651 00 Connector REMOTE IN 1 561 749 00 Shell RCC 5G 10G 30G cable 3 1 5C 2V Max 100 meters Fujikura America Inc Fujikura ...

Page 8: ... 270 Mbps Conform to SMPTE 259M ITU R BT 656 SUB BNC x 1 Component digital 270 Mbps Conform to SMPTE 259M ITU R BT 656 6 GPI EFFECT KEY ON KEY OFF BNC x 3 GPI input for effect control TTL Level 10 k Z Output Connector 2 MONITOR OUT BNC x 1 Analog composite video 1 0 V p p 75 Z sync negative 3 PROGRAM OUT BNC x 4 Component digital 270 Mbps Conform to SMPTE 259M ITU R BT 656 1 5 Input and Output Sig...

Page 9: ...terface Mouse control 8 ISR D sub 25 pin connector RS 232C interface For ISR Interactive Status Reporting 9 REMOTE OUT D sub 9 pin connector RS 422A interface Remote control REMOTE IN D sub 9 pin connector RS 422A interface Remote control 1 5 Input and Output Signal of Connector ...

Page 10: ...XD Received Data Input 4 RTS Request to Send Output 5 CTS Clear to Send Input 6 DSR Data Set Ready Input 7 SG Signal Ground 8 DCD Data Carrier Detect Input 9 to 19 NC 20 DTR Data Terminal Ready Input 21 to 25 NC 9 9 9 9 9 REMOTE OUT RS 422A D sub 9 pin Female Pin No Signal 1 GND 2 RM RX _ 3 RM TX 4 GND 5 SPARE 6 GND 7 RM RX 8 RM TX _ 9 GND REMOTE IN RS 422A D sub 9 pin Female Pin No Signal 1 GND 2...

Page 11: ...tch on the SEC 54 and VSW 61 boards IF 643 board n The addresses on the board are shown by marks S600 A 9 RESET switch Resets the CPU on the IF 643 board S700 A 9 MODE SELECT switch Factory setting All switch levers are set to OFF 1 6 Switch Setting on Connector Panel 1 7 Switch Setting on Board ON OFF 75 Z REF VIDEO 75 Z termination switch ON 1 2 3 4 5 6 7 8 indicates the switch lever position 1 ...

Page 12: ...ke sure that all the units in the rack should be operat ed within the temperature range of 5 dC to 40 dC Connect the enough long cables on the rear panel considering that the DEP 100 is pulled out An installation manual is supplied with the RMM 30 rack mount rail However follow the instructions in this manual Because the rack mounting procedures of the DEP 100 differ somewhat from the procedures e...

Page 13: ... 100 using the six screws B4 x 8 supplied with the DEP 100 5 Loosen the screws fastening the rear bracket to the outer rail and adjust the position of the rear bracket with the rack depth 6 Attach the front and rear brackets to the outside of the rack temporarily using the eight screws B5 x 8 supplied with RMM 30 Rack Rack Unit mm 12 7 12 7 31 75 12 7 31 75 B5 x 8 Outer rail B5 x 8 1 8 Rack Mounti...

Page 14: ...s B5 x 8 secured tempo rarily in the step 6 n When securing the front brackets to the rack by screws pull out the DEP 100 about 20 cm 8 inches and fasten the screws of the front brackets to the rack 9 After installing the DEP 100 in the rack secure the unit to the rack by the prepared four screws RK5 x 16 and four washers n When the DEP 100 is mounted in a rack the maximum traveling distance is il...

Page 15: ... 2 Service Overview 5 Clean the dust on the filter using a vacuum cleaner n If the filter is too much dusty it is recommended to wash it When washing the filter be sure to dry it well 6 After cleaning fasten the filter to the tapes 2 2 Periodic Replacement To maintain the performance of the DEP 100 it is recom mended to replace the fan motor periodically Fan motor A fan motor is installed on the r...

Page 16: ...EM indicator Lights off 525 60 system Lights up 625 50 system D500 to D503 green A 7 8 Factory use D504 to D507 red A 8 Factory use D703 to D706 red A 10 Unassigned D707 red A 10 SYSTEM CONTROL ERROR indicator Lights up when CPU does not run normally D708 green A 11 SYSTEM CONTROL STATUS indicator Blinks when CPU runs normally 2 3 Information of LEDs on Board 1 2 3 4 5 6 7 8 9 10 11 12 A B C IF 64...

Page 17: ...tion program software For the program software usage installation and opera tion of a personal computer in which this program software can be used please consult with your local Sony s sales service office The preparation below is required when managing the DEP 100 by ISR 1 Connect a personal computer to the ISR connector D sub 25 pin of the DEP 100 using a RS 232C cross cable 2 Check the DIP swit...

Page 18: ...nd descriptions are as follows Test No Description 1 Initial Self Diagnostics 2 VSW 45 board sense 3 SEC 39 board sense 4 Flash memory It can be requested these self diagnostics menus by using HELP TST command When the self diagnostics is complete the DEP 100 returns ATN OPC 2 4 3 Supported Commands The DEP 100 supports the following commands For more detailed information of each command refer to ...

Page 19: ...re module which downloaded is stored in flash memory The DEP 100 operates with this software module from next boot up When downloading is complete the DEP 100 returns ATN OPC TST Test Query This command requests the results of the self diagnostic stored in the buffer The responses for each self diagnostics are as follows 1 Initial Self Diagnostics No error Error occurred 2 VSW 45 board sense Exist...

Page 20: ......

Page 21: ...des acquéreurs de l équipement décrit dans ce manuel Sony Corporation interdit formellement la copie de quelque partie que ce soit de ce manuel ou son emploi pour tout autre but que des opérations ou entretiens de l équipement à moins d une permission écrite de Sony Corporation Das in dieser Anleitung enthaltene Material besteht aus Informationen die Eigentum der Sony Corporation sind und ausschli...

Page 22: ...Printed in Japan Sony Corporation 1997 10 08 Broadcast Products Company 1997 Published by Broadcast Products Company DEP 100 SY J E 3 193 433 01 ...