CXD5602 User Manual
-
280/1010
-
3.9.9.1
Startup Control
SCU_REG
SEQUENCER
Generate signal
about request
for Startup
Configuration
Data
assertion of
Trigger Singal
or
Interrupt
signal
10 instruction group
3 instruction group
Configuration
to sequencer
request
completion
notice
Read
Sensor
Data
Data
formatting
and
Control
FIFO
MATH_PROC
SCU_FIFO
Configuration
Data
10 configuration
data set
Data formatting
10 configuration
data set
Writing to FIFO
Setting
16 configuration
data set
SPI Master
I2C Master 0 I2C Master 1
LPADC
HPADC0
HPADC1
Figure SCU (Sensor Control Unit)-72 Startup Control
A startup request occurs for each SEQ_ID under any of the following conditions.
A certain cycle by the timer
A certain cycle by the timer after receiving an external interrupt as the trigger
One operation using an external interrupt as the trigger
One operation using the register writing operation as the trigger, which is from the CPU
The startup intervals by the timer can be selected using the frequency division value of the Pre Divider that
determines the startup maximum frequency.
The operating frequency of each sequencer can be selected by the frequency of the 2nd power of the frequency
divided by the Pre Divider.
When the sequencer is started up by the startup request, the process is branched into each physical interface
shown below according to the setting value that is set on the SCU_RAM and hands over the external bus
transaction process.
SPI
I2C0
I2C1
When either LPADC or HPADC is selected as the physical interface, it does not branch into the external bus
transaction generation process, and the sequencer control program moves to external data capture process.