– 4 –
TAP701
TAP702
TP(RF)
– CD board (conductor side) –
TP
(RF)
CD SECTION
CD section adjustments are done automatically in this set.
In case of operation check, confirm that focus bias.
FOCUS BIAS CHECK
1. Connect the oscilloscope between IC701 pin
wj
(or TP (RF))
and GND on CD board.
2. Insert the disc (YEDS-18). (Part No. : 3-702-101-01)
3. Press the CD
N
X
button.
4. Confirm that the oscilloscope waveform is as shown in the
figure below. (eye pattern)
A good eye pattern means that the diamond shape ( ) in the
center of the waveform can be clearly distinguished.
• RF signal reference waveform (eye pattern)
Test Point:
When observing the eye pattern, set the oscilloscope for AC range
and raise vertical sensitivity.
2. ELECTRICAL ADJUSTMENT
RF level :
0.9 - 1.5 Vp-p
VOLT/DIV : 50 mV (10 : 1 probe in use)
TIME/DIV : 500 nS