22
CDX-GT71W/GT710/GT760
SECTION 4
DIAGNOSIS FUNCTION
Description of the Diagnostics function:
1. Setting the Diag display mode
With the power off, press the
[4]
button,
[5]
button, and
[4]
button
on the set body or the remote control (for more than 2 seconds)
in turn.
2. Canceling the Diag display mode
During the Diag function mode, press the
[OFF]
button.
3. Initial display in the Diag display mode.
Just when the Diag mode is entered, “reset count” is displayed.
The display mode is switched by each rotation of
SEEK +/
M
>
or SEEK – /
.
m
keys.
4. Contents of each display mode
4-1. Reset count display mode
4-2. Reset count by watchdog timer display mode
4-3. Number of connected units display mode
The display mode is switched by each rotation of
[4/GP/ALBM+]
or
[3/GP/ALBM--]
keys during the number of connected units display
mode.
01
XX
DIAG
02
XX
DIAG
03
XXX
DIAG
04
XXXX
DIAG
05
XX
DIAG
06
1XXXXX
1
1
DIAG
Reset count display
OFFSET/FAILURE error display
CD error information display
Operating hours display
Number of connected units display
Reset count by watchdog timer display
01
XX
DIAG
Reset count
(in hexadecimal format)
Diag code
01: Reset count
02
XX
DIAG
Reset count
(in hexadecimal format)
Diag code
02: Number of resets by watchdog timer
Show the number of connected units for
CD-C, MD-C and XM respectively from
the rightmost (in hexadecimal format).
Recency of information
1-3: 1 represents the latest.
Diag code
03: Number of connected unit.
03
XXX
1
DIAG
03
XXX
1
DIAG
03
XXX
2
DIAG
03
XXX
3
DIAG
No. of connected units history 1 (latest) display
No. of connected units history 3 display
No. of connected units history 2 display
Summary of Contents for CDX-GT710 - Fm-am Compact Disc Player
Page 58: ...58 CDX GT71W GT710 GT760 MEMO ...