– 15 –
AM RF signal
generator
antenna
terminal
AM dummy
antenna (50
Ω
)
30
Ω
65 pF
15 pF
set
MW Auto Scan/Stop Level Adjustment
Setting :
SOURCE
n
MODE button : MW
Procedure :
1. Set to the test mode. (See page 13.)
2. Push the SOURCE button.
3. Push the MODE button and set to MW.
Display
4. Push the preset 3 button.
Display
5. Adjust with the volume RV1 on TU701 so that the “MW”
indication turns to “MW0” indication on the display window.
But, in case of already indicated “MW0”, turn the RV1 so that
put out light “0” indication and adjustment.
Display
Carrier frequency : 999 kHz
30% amplitude
modulation by
1 kHz signal
output level
: 33 dB (44.7
µ
V)
Adjustment Location : See page 16.
EL
D
EL
D
EL
D
Carrier frequency : 98.0 MHz
Output level
: 35 dB (56.2
µ
V)
Mode
: mono
Modulation
: no modulation
Procedure :
1. Set to the test mode. (See page 13.)
2. Push the SOURCE button and set to FM.
Display
FM RDS S-Meter Adjustment
Setting :
SOURCE button : FM
3. Push the preset 10 button.
4. Adjust RV701 so that the display indication is “13.0”.
Display
Specification : Display indication : 12.8 to 13.2.
Adjustment Location : See page 16.
FM RF signal
generator
antenna
terminal
0.01
µ
F
set
EL
D
EL
D
www. xiaoyu163. com
QQ 376315150
9
9
2
8
9
4
2
9
8
TEL 13942296513
9
9
2
8
9
4
2
9
8
0
5
1
5
1
3
6
7
3
Q
Q
TEL 13942296513 QQ 376315150 892498299
TEL 13942296513 QQ 376315150 892498299