25
CDP-CX455
Mechanical Adjustments
Pop Up Mechanism Adjustment
1.
Turn on the power and set the disc to number 24.
2.
With the power ON, while pres sing the TIME and MEGA
CONTROL buttons, press the
1/u
button to enter the test mode.
3.
Rotate the JOG dial and select “CDM Test”.
Press the JOG dial.
4.
Rotate the JOG dial and select the mechanism adjustment mode.
(“Mech Adjust” is displayed.)
Press the JOG dial.
5.
Keep pressing the TOP ARTIST 1 button to operate the loading
mechanism, and continue pressing until the disc table locks.
(Fig. 1)
6.
Keep pressing the TOP ARTIST 2 button to raise the pop up
part.
7.
Loosen the adjusting screw, move the screwdriver left and right
until the lever (POP UP) does not touch the slit wall, and secure
the screw. (Fig. 2)
The following buttons have special functions in this mode.
TOP ARTIST 1 button: Loading mechanism IN operation
TOP ARTIST 5 button: Loading mechanism OUT operation
TOP ARTIST 2 button: Pop up part UP operation
TOP ARTIST 6 button: Pop up part DOWN operation
At this position,this
part will be locked.
Lever (POP-UP 400)
Fix to the center so that the
lever (POP-UP 400) does
not touch the slit.
Cover (chassis 400)
Fig. 1
Fig. 2
SECTION 5
ADJUSTMENTS
Table Sensor Adjustment
1.
Enter the CDM Test mode and select “Mech Adjust” with the
JOG dial, and press the dial.
2.
Press the TOP ARTIST 1 button to operate the loading mechanism,
and continue pressing until the disc table locks. (Fig. 3)
3.
Loosen the fixing screw and move the holder so that both PLAY
button LED (green) and the ALBUM SELECT button LED
(green) light.
If the holder is not in the correct position, the MEGA
CONTROL button LED (orange) or the PAUSE button LED
(orange) lights.
4.
Moving the disc table right and left with a hand after the screw
is fixed, the table will move by the play of a disc table. If the
LEDs light up alternately, the adjustment will be performed
correctly. (Fig. 4)
MEGA CONTROL
ALBUM SELECT
Fig. 3
Fig. 4
Holder (table sensor 400)
S tight, screw
(PTTWH 3
×
6)
Swing
Table (400) assembly
At this position,this
part will be locked.