background image

COMPUTING UNIT

BCU-100

MEMORY EXTENSION ADAPTER

BKCU-EX1

MEMORY MODULE 8GB

BKCU-MY8D

VIDEO DISPLAY BOARD

BKCU-VD1

INSTALLATION MANUAL
1st Edition (Revised 1)

Summary of Contents for BCU-100

Page 1: ...COMPUTING UNIT BCU 100 MEMORY EXTENSION ADAPTER BKCU EX1 MEMORY MODULE 8GB BKCU MY8D VIDEO DISPLAY BOARD BKCU VD1 INSTALLATION MANUAL 1st Edition Revised 1 ...

Page 2: ...als die angegeben Wartungsarbeiten dürfen nur von Personen ausgeführt werden die eine spezielle Befähigung dazu besitzen AVERTISSEMENT Ce manual est destiné uniquement aux personnes compétentes en charge de l entretien Afin de réduire les risques de décharge électrique d incendie ou de blessure n effectuer que les réparations indiquées dans le mode d emploi à moins d être qualifié pour en effectue...

Page 3: ...ipment while taking the operating temperature of the equipment into consideration For the operating temperature of the equipment refer to the specifications of the Installation Manual 6 When performing the installation keep the following space away from walls in order to obtain proper exhaust and radiation of heat Rear 10 cm 4 inches or more WARNING When installing the unit incorporate a readily a...

Page 4: ......

Page 5: ...d BKCU MY8D 1 3 E 1 4 2 Installing the BKCU VD1 1 4 E 1 5 Rack Mounting 1 5 E 1 5 1 Precautions for Rack Mounting 1 5 E 1 5 2 Rack Mounting Procedure 1 6 E 1 6 Installing the Power Cord Extract Stopper 1 7 E 1 7 Matching Connectors and Cables 1 8 E 1 8 Input and Output Signals of Connectors 1 9 E 1 9 Setting the On Board Switches and Description of LEDs 1 11 E 2 Setup of Software 2 1 Installing th...

Page 6: ......

Page 7: ...plication and operation of BCU 100 Technical Manual Available on request This manual describes the system software for the BCU 100 For obtaining contact your local Sony Sales Office Service Center Maintenance Manual Available on request This manual describes detailed parts list block diagrams schematic diagrams and board layouts required for parts level service For obtaining contact your local Son...

Page 8: ......

Page 9: ... temperature 10 dC to 35 dC Operating humidity 20 to 90 relative humidity Storage temperature _20 dC to 60 dC Mass Approx 11 5 kg with all options installed Prohibited locations for installation Areas where the unit will be exposed do direct sunlight or any other strong lights Dusty areas Areas is subject to vibration Areas with strong electric or magnetic fields Areas near heat sources Areas subj...

Page 10: ...1 2 E BCU 100 IM Unit mm 1 3 Installation Space External dimensions 440 43 6 551 2 482 465 115 5 115 5 177 7 36 31 8 ...

Page 11: ...r BKCU EX1 and memory module 8 GB BKCU MY8D to the BCU 100 BKCU EX1 components MEM 122 board 1 Screw PSW3 x 6 2 BKCU MY8D components 4GB DDR2 SDRAM DIMM 2 Note when installing BKCU MY8D When installing the memory modules touch a metal portion of the BCU 100 to eliminate the Electrostatic Discharge ESD in your body before starting the installa tion work to prevent damage to the memory modules 3 Tur...

Page 12: ...tall the top panel PSW3 x 6 CN2 PSW3 x 6 MEM 122 board EX 1076 board 1 4 2 Installing the BKCU VD1 This section describes the method to install the video display board BKCU VD1 to the BCU 100 BKCU VD1 components VIF 40 board 1 Screw PSW3 x 6 2 Installation procedure 1 Remove the top panel Refer to section 1 4 1 2 Remove the two screws and remove the VIF blank panel B3 x 6 VIF blank panel ...

Page 13: ...ack angle and fix the unit in the rack If the screws on the rack angle are not tightened the unit may slip from the rack and fall causing injury c When mounting the unit in the rack note the following Be sure to mount in the rack with two persons or more Be careful not to catch your fingers or hands in the rack mount rail or others Mount in the rack in a stable position n If several units are moun...

Page 14: ...t using the specified six screws n Use B4 x 6 screws 2 Loosen the screws on the rear of the right and left adaptors and adjust the length of the adaptor according to the depth of the rack The illustration below shows the left adaptor n Maximum depth of adaptor 750 mm Minimum depth of adaptor 595 mm B4 x 6 Portion of the rail Adaptor Rack tool B4 x 6 Rack tool B4 x 6 B5 x 12 B5 x 12 Rack Rack angle...

Page 15: ...ccidentally coming off while the power is supplied to the BCU 100 1 Insert portion A of the extract stopper into the hole of the AC inlet Push portion B and insert portion C to secure it 2 Move the extract stopper in the direction of the arrow 3 Insert the power cord into the AC inlet 4 Move the extract stopper in the direction of the arrow and fix the power cord A C B Extract stopper Extract stop...

Page 16: ..._ MAINTENANCE DVI I DVI I 29 pin Female Digital connection DVI cable for digital single link 3 when the BKCU VD1 A ferrite core is attached is installed Analog connection DVI cable for analog connection 4 5 A ferrite core is attached 1 Conforms to the IEEE 802 3 Ethernet 10BASE T 100BASE TX 1000BASE T standards 2 The following crimp contact is required for the socket AWG 24 to 26 1 563 814 11 3 DV...

Page 17: ... Function name Output 1 VBUS _ USB Vcc 2 D_ I O USB Data _ 3 D I O USB Data 4 GND _ Ground 8 1 _ EXT VIEW _ _ EXT VIEW _ 4 1 RS 232C RS 232C D sub 9 pin Male Pin No Signal Input Function name Output 1 _ _ No connection 2 RXD I Received data 3 TXD O Transmitted data 4 DTR O Data terminal ready 5 GND _ Ground 6 DSR I Data set ready 7 RTS O Request to send 8 CTS I Clear to send 9 _ _ No connection MA...

Page 18: ...ction 14 5V _ Power for Monitor when in standby 15 GND _ Return for 5V and analog sync Ground 16 Hot Plug Detect I Hot Plug Detect 17 TMDS Data 0 O Digital Blue _ 18 TMDS Data 0 O Digital Blue 19 TMDS Data 0 Shield _ Shield for Data 0 Ground 20 _ _ No connection 21 _ _ No connection 22 TMDS Clock Shield _ Shield for Clock Ground 23 TMDS Clock O Digital Clock 24 TMDS Clock_ O Digital Clock _ C1 Ana...

Page 19: ... pressed for 2 seconds during operation Same action as that of the Power switch on the front panel S6503 F 6 Reset The system is reset when pressed during _ operation Same action as that of the Reset switch on the front panel LED Ref No Address Name Indication Function Normal state color D6511 A 1 Beacon Blue Lights in blue when the Beacon command is received Lights off Blinks in blue when the Bea...

Page 20: ...omatically starts when the AC power turns on OFF Does not start automatically S102 3 Sets the starting path ON Forcibly starts in the maintenance mode OFF Starts with the path set on the firmware S102 4 to 6 Not used S102 7 8 Sets the RS 232C function 1 S103 B 2 Side B Beacon Pushes when turning on BEACON LED _ 1 Setting the RS 232C function S102 7 S102 8 Front side RS 232C Rear side RS 232C OFF O...

Page 21: ...ide B 2 to 5 Green Displays the error status when D107 lights or blinks 3 Lights off 111 D112 B 2 Side B Beacon Blue Lights in blue when the Beacon command is received Lights off Blinks in blue when the BEACON switch is pressed 1 State POWER LED Message LED Power off Lights off Lights off AC power on Lights in red Lights off Standby state Power UP operation Blinks in green Lights off Firmware star...

Page 22: ... Ref No Address Name Function Factory setting S200 E 4 Side A Reset Resets the MEM 122 board _ S900 D 4 _ S900 1 to 8 Factory use All OFF ON 1 2 3 4 5 6 7 8 indicates the knob position Side B S900 S200 D908 D400 D401 D402 D403 D404 D405 D406 D407 D900 D901 D902 D903 D904 D905 D906 D907 F E D C B A 1 2 3 4 ...

Page 23: ...D Status Green Always lit Lights on D901 F 4 Green Lights when FPGA operates normally Lights on D902 F 4 Green Lights when saving in the flash memory is Lights off complete D903 F 4 Green Lights when the flash memory is cleared Lights off D904 F 4 Green Lights when FPGA operates normally Lights on D905 F 4 Green Lights when FPGA operates normally Lights on D906 F 4 Green Lights when FPGA operates ...

Page 24: ......

Page 25: ...ng the Software No operating system is preinstalled on the BCU 100 in its default state For installing software including an operation system refer to the technical manual For obtaining the technical manual contact your local Sony Sales Office Service Center ...

Page 26: ......

Page 27: ...panel and check for the state of error LED 1 State Message LED Error LED 1 Warning 1 Blinks in blue Blinks in red Error 2 Blinks in red Lights in red 1 A state where a less urgent abnormality such as fan rotation drop or a warning for replacement time is detected 2 A state where the machine has been shut down after an abnormality with high urgency such as power failure or temperature rise has been...

Page 28: ...E chip on the BE 28 board has a problem 8 Light Blink Action around the RSX chip on the BE 28 board has a problem 9 Light Blink Not used A Light Blink Not used B Light Blink Not used C Light Blink Not used D Light Blink The lithium battery on the BE 28 board has a problem E Light Blink The system control has a problem F Light Blink The system control is operating in backup mode Note When LED 1 is ...

Page 29: ...nce 3 2 1 Cleaning 1 Front panel BCU 100 is performing the air intake from the front panel for internal air cooling Therefore the front panel can easily accumulate dust Be sure to remove dust by cleaning If dust has accumulated in the front panel air is prevented from flowing smoothly and this may result in a tempera ture rise inside the unit This may have an adverse effect on performance and life...

Page 30: ... for replacing each part refer to the maintenance manual Part name Replacement Remarks period Fan About 4 years The inside of unit Power supply About 4 years unit Replacement period of the fans and power supply unit The cumulative usage time of the fans and the power supply unit inside the BCU 100 is separately measured and an alarm is issued when the usage time is about to be expired Refer to 3 1...

Page 31: ...é de Sony Corporation Sony Corporation interdit formellement la copie de quelque partie que ce soit de ce manuel ou son emploi pour tout autre but que des opérations ou entretiens de l équipement à moins d une permission écrite de Sony Corporation Das in dieser Anleitung enthaltene Material besteht aus Informationen die Eigentum der Sony Corporation sind Die Sony Corporation untersagt ausdrücklich...

Page 32: ...Printed in Japan Sony Corporation 2008 7 16 2008 BCU 100 SY J E 3 299 378 02 ...

Reviews: